Table of Contents | ||||||
---|---|---|---|---|---|---|
|
...
read/execute permissions in %HYPERSIM_DIR%.
Most HYPERSIM processes start from this location, the main ones being:
Process name | Usage | Ports | Permission notes |
---|---|---|---|
Hyperworks.exe | Design interface | 13510, 32768-65535 | You need an internet connection to use the target manager to request a target license |
HyWorks.exe | Main HYPERSIM application | 111, 600-1023, 13510 | |
HyCore.exe | Target interaction application | 111, 600-1023, 13500, 32768-65535 | |
ActivationTool.exe | Host license installation | 111, 600-1023 | You need an internet connection to use the ActivationTool to request a host license |
IOGuiFX.exe | 111, 600-1023, 17510 | ||
Scopeview.exe | ScopeView software | 111, 600-1023, 13501 | |
TestView.exe | TestView software | 111, 600-1023 | |
UcmBuilder.exe | UCM editor tool | 111, 600-1023 | |
Diagnostic_Tool | Setup analyzing tool | Needs to be run as an administrator in order to give a complete report. | |
hyServMain.exe | Simulation setup and interface | 17510, 49152-65535 | |
hypersim.exe | Circuit engine application | 600-1023, 32768-49151 | |
eclipse.exe | DocCenter application | 49152-65535 |
The executables above may start any executable in %HYPERSIM_DIR%. They need to be authorized through the firewall.
...
HYPERSIM is compatible with all our Real-Time Hardware-in-the-Loop Simulator platforms. The system requirements of the platform will depend on the application and simulation demands.
For more information on our hardware platforms, please refer to our Hardware Products Documentation Home, or follow the links below.
For more information on our hardware platforms, please refer to our Hardware Products Documentation Home, or follow the links below.
Compact Desktop Simulators
Complete Simulation Systems
Linux Operating Systems
OPAL-RTLinux 3
CentOS 6.6 (build 3.12.26-opalrt)
...
Warning |
---|
End of support
|
Permissions
Target permissions are configured before delivery, or during the first HYPERSIM installation on target.
Target (Windows)
Since HYERSIM 2021.3.0, multi-user mode is available on Windows targets in accelerated simulation (RTA) mode.
If you're interested in testing the feature and providing feedback, please contact the support team.
Operating System
Windows 10 or 11