Connected I/O module is OP5369 32-Channel Digital IO Board

...

Note

Before designing cables, OPAL-RT recommends using the guideline Simulator EMC cable recommendations.
Before connecting the cables, make sure that the voltages or other electrical specifications are compatible with OPAL-RT DB37specifications of I/O module OP5369.

Connector P1
Group 1 - Section A - Channel 00 to 15

 

 

image-20240610-151219.png

Connector P2
Group 1 - Section A - Channel 16 to 31

DB37F Pin

Assignment

DB37F Pin

Assignment

DB37F Pin

Assignment

DB37F Pin

Assignment

1

+D00

20

GND

1

+D16

20

GND

2

+D01

21

GND

2

+D17

21

GND

3

+D02

22

GND

3

+D18

22

GND

4

+D03

23

GND

4

+D19

23

GND

5

+D04

24

GND

5

+D20

24

GND

6

+D05

25

GND

6

+D21

25

GND

7

+D06

26

GND

7

+D22

26

GND

8

+D07

27

GND

8

+D23

27

GND

9

+D08

28

GND

9

+D24

28

GND

10

+D09

29

GND

10

+D25

29

GND

11

+D10

30

GND

11

+D26

30

GND

12

+D11

31

GND

12

+D27

31

GND

13

+D12

32

GND

13

+D28

32

GND

14

+D13

33

GND

14

+D29

33

GND

15

+D14

34

GND

15

+D30

34

GND

16

+D15

35

GND

16

+D31

35

GND

17

+12 V*

36

GND

17

+12 V*

36

GND

18

Vuser 1

37

Vrtn 1

18

Vuser 2

37

Vrtn

19

Not used

19

Not used

* Internally provided by the simulator. Non-isolated, limited to 400 mA.

Info

If used as digital output, channels will require a Vuser reference of 4.5 to 24 Vdc max (default internal 4.5 volts), which is provided through the DB37 connector pin 18 and referenced to Vrtn pin 37.

The OP5369 32-channel digital IO board can be configured per 8-channel subsection to be used as digital inputs or digital outputs. The following table is a list of parameters to configure as input or output.

...

DIGITAL INPUT BLOCK PARAMETERS

Parameters

CH00-07

CH08-15

CH16-23

CH24-31

Controller Name

'OP4512 OpCtrl'

Data Out Port Number

3

4

5

6

Number of channels

8

8

8

8

Digital Input Type

  • Static Digital In

  • Event Detector

  • Pulse-Width Modulated Input

  • Static Digital In

  • Event Detector

  • Pulse-Width Modulated Input

  • Static Digital In

  • Event Detector

  • Pulse-Width Modulated Input

  • Static Digital In

  • Event Detector

  • Pulse-Width Modulated Input

Info

In addition to the parameters listed above, other parameters may need to be configured. More information on the Din and Dout parameters can be found here: OP5369 32-Channel Digital IO Board.