Documentation Home Page HIL2GO Main Menu
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Current »

Connected I/O module is OP5369 32-Channel Digital IO Board

image-20240509-210430.png

Before designing cables, OPAL-RT recommends using the guideline Simulator EMC cable recommendations.
Before connecting the cables, make sure that the voltages or other electrical specifications are compatible with OPAL-RT DB37 specifications of I/O module OP5369.

Connector P1
Group 1 - Section A - Channel 00 to 15

 

 

image-20240610-151219.png

Connector P2
Group 1 - Section A - Channel 16 to 31

DB37F Pin

Assignment

DB37F Pin

Assignment

DB37F Pin

Assignment

DB37F Pin

Assignment

1

+D00

20

GND

1

+D16

20

GND

2

+D01

21

GND

2

+D17

21

GND

3

+D02

22

GND

3

+D18

22

GND

4

+D03

23

GND

4

+D19

23

GND

5

+D04

24

GND

5

+D20

24

GND

6

+D05

25

GND

6

+D21

25

GND

7

+D06

26

GND

7

+D22

26

GND

8

+D07

27

GND

8

+D23

27

GND

9

+D08

28

GND

9

+D24

28

GND

10

+D09

29

GND

10

+D25

29

GND

11

+D10

30

GND

11

+D26

30

GND

12

+D11

31

GND

12

+D27

31

GND

13

+D12

32

GND

13

+D28

32

GND

14

+D13

33

GND

14

+D29

33

GND

15

+D14

34

GND

15

+D30

34

GND

16

+D15

35

GND

16

+D31

35

GND

17

+12 V*

36

GND

17

+12 V*

36

GND

18

Vuser 1

37

Vrtn 1

18

Vuser 2

37

Vrtn

19

Not used

19

Not used

* Internally provided by the simulator. Non-isolated, limited to 400 mA.

If used as digital output, channels will require a Vuser reference of 4.5 to 24 Vdc max (default internal 4.5 volts), which is provided through the DB37 connector pin 18 and referenced to Vrtn pin 37.

The OP5369 32-channel digital IO board can be configured per 8-channel subsection to be used as digital inputs or digital outputs. The following table is a list of parameters to configure as input or output.

I/O MODULE OPTION BLOCK

Parameters

CH00-07 / CH08-15 / CH16-23 / CH24-31

Controller Name

'OP4512 OpCtrl'

Mezzanine-type I/O module

OP5369 - 32 DIO

Direction

Input

Output

Threshold low (volt)

0.470 to 29.4 V

N/A

Threshold high (volt)

0.470 to 29.4

N/A

DIGITAL OUTPUT BLOCK PARAMETERS

Parameters

CH00-07

CH08-15

CH16-23

CH24-31

Controller Name

'OP4512 OpCtrl'

Data In Port Number

11

12

13

14

Number of channels

8

8

8

8

Digital Output Type

  • Static Digital Out

  • Event Generator

  • Pulse-Width Modulated Output

  • Static Digital Out

  • Event Generator

  • Pulse-Width Modulated Output

  • Static Digital Out

  • Event Generator

  • Pulse-Width Modulated Output

  • Static Digital Out

  • Event Generator

  • Pulse-Width Modulated Output

DIGITAL INPUT BLOCK PARAMETERS

Parameters

CH00-07

CH08-15

CH16-23

CH24-31

Controller Name

'OP4512 OpCtrl'

Data Out Port Number

3

4

5

6

Number of channels

8

8

8

8

Digital Input Type

  • Static Digital In

  • Event Detector

  • Pulse-Width Modulated Input

  • Static Digital In

  • Event Detector

  • Pulse-Width Modulated Input

  • Static Digital In

  • Event Detector

  • Pulse-Width Modulated Input

  • Static Digital In

  • Event Detector

  • Pulse-Width Modulated Input

In addition to the parameters listed above, other parameters may need to be configured. More information on the Din and Dout parameters can be found here: OP5369 32-Channel Digital IO Board.

  • No labels