Table of Contents | maxLevel | 1|||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Table of Contents | ||||||||||||||
|
Host PC
Performance Requirements
Category | Minimum | Recommended |
---|---|---|
Operating System | Windows 10 or 11 (64-bit only) | Windows 10 or 11 (64-bit only) |
Processor | Any Intel or AMD x86-64 processor | At least 2 logical cores are required to run a simulation. Any additional core can be used to accelerate a simulation or run multiple simulations in parallel. |
RAM | 16 GB | 32GB |
Disk |
If you run the simulation on localhost you must have at least 5 GB left on your computer. If you run in real-time you must have at least 5 GB left on the target. | An SSD |
Graphics | No minimum | No recommendation |
Permission Requirements
In the following sections, the following symbols are used:
%HYPERSIM_DIR%: The path to the HYPERSIM installation.
By default, this value is C:\OPAL-RT\HYPERSIM\hypersim_version ; where hypersim_version is the folder of the current version, for example, "hypersim_2021.3.1.o187".
%USERPROFILE%: The user directory. By default, this value is C:\Users\userName; where userName is the Windows user name, for example, "JohnSmith"
Note 1: HYPERSIM currently does not support spaces in this path.
Note 2: In some rare cases, user names with capital letters may trigger errors when writing to the target code directory. If such an issue occurs, please use the Target manager Manager Diagnostic to get additional information.
...
Process name | Usage | Ports | Permission notes |
---|---|---|---|
Hyperworks.exe | Design interface | 13510, 32768-65535 | You need an internet connection to use the target manager to request a target license |
HyWorks.exe | Main HYPERSIM application | 111, 600-1023, 4569, 13510 | 4569 used by the sequencer tool |
HyCore.exe | Target interaction application | 111, 600-1023, 13500, 32768-65535 | |
ActivationTool.exe | Host license installation | 111, 600-1023 | You need an internet connection to use the ActivationTool to request a host license |
IOGuiFX.exe | 111, 600-1023, 17510 | ||
Scopeview.exe | ScopeView software | 111, 600-1023, 13501 | |
TestView.exe | TestView software | 111, 600-1023 | |
UcmBuilder.exe | UCM editor tool | 111, 600-1023 | |
Diagnostic_Tool | Setup analyzing tool | n/a | Needs to be run as an administrator in order to give a complete report. |
hyServMain.exe | Simulation setup and interface | 17510, 49152-65535 | |
hypersim.exe | Circuit engine application | 600-1023, 32768-49151 | |
psql.exe | Tool to enable queries on the database server |
The executables above may start any executable in %HYPERSIM_DIR%. They need to be authorized through the firewall.
...
%USERPROFILE%/My Documents/HYPERSIM is the default location suggested for creating HYPERSIM models.
Make sure any selected location or pathname is not very long--otherwise, the generated files may exceed Windows path length limitations.
Logs and user preferences are stored in %USERPROFILE%/HYPERSIM.
The localhost target default code generation is in the %USERPROFILE%/HYPERSIM folder. A process with the name of the model starts from this location.
Running a simulation, on localhost or on a target, may use ports 17511 through 17599 for interaction with I/O Interfaces.
...
This step is only required for versions 2021.3 and earlier. To communicate with a Linux target, users need to must ensure their SAMBA permissions are sufficient. Specifically, they need the option below enabled. If this option is missing, the Diagnostic_Tool can provide a solution on how to install for installing it.
...
Background Color | ||
---|---|---|
| ||
UDP ports 137, 138 and TCP ports 139 and 445 must be freed for the successful running of HYPERSIM, as Windows 10 disables them by default in certain configurations (e.g. guest access). Please contact your IT department in case of issues with Samba2. HYPERSIM uses UDP protocol on ports 137-138 and TCP ports 139, 445 to exchange information between the localhost and the target. For more, read: https://support.microsoft.com/en-us/help/4046019/guest-access-in-smb2-disabled-by-default-in-windows-10-and-windows-ser |
Insert excerpt | ||||||
---|---|---|---|---|---|---|
|
Target (
...
Hardware Platforms
HYPERSIM is compatible with all our Real-Time Hardware-in-the-Loop Simulator platforms. The system requirements of the platform will depend on the application and simulation demands.
For more information on our hardware platforms, please refer to our Hardware Products Documentation Home, or follow the links below.
For more information on our hardware platforms, please refer to our Hardware Products Documentation Home, or follow the links below.
Compact Desktop Simulators
Complete Simulation Systems
Real-Time Computers
Linux Operating Systems
...
Windows)
Since HYERSIM 2021.3.0, multi-user mode is available on Windows targets in accelerated simulation (RTA) mode.
If you're interested in testing the feature and providing feedback, please get in touch with the support team.
Operating System
Windows 10 or 11
Target (Linux)
Permissions
Target permissions are configured before delivery, or during the first HYPERSIM installation on target.
Linux Operating Systems
OPAL-RTLinux 3
OPAL-RTLinux 3.5.4 | OPAL-RTLinux 3.4.1 | OPAL-RTLinux 3.5.4 (x86-based) | |
---|---|---|---|
HYPERSIM 2024.2 and newer | |||
HYPERSIM 2023.2 to 2024.1 | |||
HYPERSIM 2023.1 and older |
CentOS 6.6 (build 3.12.26-opalrt)
...
Warning |
---|
End of support
|
Permissions
Target permissions are configured before delivery, or during the first HYPERSIM installation on target.
Target (Windows)
Since HYERSIM 2021.3.0, multi-user mode is available on Windows targets in accelerated simulation (RTA) mode.
If you're interested in testing the feature and providing feedback, please contact the support team.
Operating System
...
Hardware Platforms
HYPERSIM is compatible with all our Real-Time Hardware-in-the-Loop Simulator platforms. The system requirements of the platform will depend on the application and simulation demands.
For more information on our hardware platforms, please refer to our Hardware Products Documentation Home, or follow the links below.
Compact Desktop Simulators
Complete Simulation Systems
Real-Time Computers
HYPERSIM vs OPAL-RT Chassis (Target Nodes)
OP5033XG (no FPGA | OP5030 (no FPGA | OP5707XG Virtex-7: VC707_2 | OP5707 Virtex-7: VC707_2 | OP5705XG Artix-7: OP5143 | OP5650 Artix-7: OP5143 | OP4610XG Kintex-7: TE0741_4 | OP4510 Kintex-7: TE0741_3 | OP5660 Virtex-6: | OP5640 Spartan-3: | |
---|---|---|---|---|---|---|---|---|---|---|
HYPERSIM 2024.2 and newer | ||||||||||
HYPERSIM 2022.1 to 2024.1 and older | ||||||||||
HYPERSIM 2021.3 and older |
HYPERSIM vs OPAL-RT Chassis (I/O Expansion Boxes)
OP4810-IO OP4815-IO Versal | OP5707-IO Virtex-7: VC707_2 | OP5607-IO Virtex-7: VC707_2 | OP7020-IO Virtex-7: VC707_1 | OP5650-IO Artix-7: | OP7000V2-IO Artix-7: | OP4610-IO Kintex-7: | OP4520-IO Kintex-7: TE0741_2 TE0741_3 | OP5660-IO Virtex-6 | OP5640-IO Spartan-3 | |
---|---|---|---|---|---|---|---|---|---|---|
HYPERSIM 2024.2 and newer | ||||||||||
HYPERSIM 2022.1 to 2024.1 and older | ||||||||||
HYPERSIM 2021.3 and older |