Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Image Removed

...

color#D3D3D3

...

If you completed the previous section of this Quick Start, you can close it now.
You are prompted to save the model you were working on.
This tutorial won’t use that model again, so click No.

...

Image Added

See also: Common Keyboard Shortcuts.

Open the model HVAC_500kV_6Bus.ecf from the Example menu located in the Transmission & Distribution category, then click Open Example.Opening an example file (Welcome page)Image Removed

...

You are then prompted to choose a destination folder for the model to be imported.
By default, this is: C:\Users\USERNAME\Documents\HYPERSIM

Click Select Folder.Choosing a directory to save the fileImage Removed

...

Once the folder is selected, HYPERSIM® HYPERSIM copies the example files to the selected folder.

You can zoom in and out of the design by using CTRL and scrolling the mouse wheel up or down.

Image Removed

...

color#D3D3D3

...

The component shown here is called a Point-On-Wave (POW) and is mandatory in all models with network components.

Image Modified

...

Image Added

It is required for time synchronization of the acquisition.
It works by monitoring one phase signal of the bus to which it is attached, so ensure that the system is always stable at that location.
Placing it adjacent to a generator helps for stability of the voltage sine wave.

...

Image Added

To visualize and edit sensors, right-click the component and click Open Sensors Form. For this example, let’s use Di1.Image Removed

...

Use the Selected checkbox to select or de-select specific sensors.Image Removed deselect specific sensors.

...

Info

In HYPERSIM, sensors play two roles:

  • They allow monitoring of the various signals across the model in ScopeView.

  • They can be used to configure analog and digital I/O as well as communication protocols.

Go to the HYPERSIM® HYPERSIM toolbar to access the sensor control.

Click Sensors & I/Os > Selected Summary in the Ribbonto see the selected sensors.

All selected sensors from the design are shown in this panel.

...

Note: In HYPERSIM®, sensors play two roles: first, they allow monitoring of the various signals across the model in ScopeView. Second, they can be used to configure analog and digital I/O as well as communication protocols.

...

Add the OPAL-RT Simulator to the target list by clicking Tools/Target Manager > TargetImage Removed

...

Click the plus sign sign + (Add Target). Image Removed

...

Enter the IP address of your target then press Ok OK.Image Removed

...

If the HyCore version is set to Unavailable, see Installing HYPERSIM on a Target from Windows.

Click Simulation > Settings on the HYPERSIM® HYPERSIM ribbon.Image Removed

...

Under Target, choose the target IP previously entered in Target Manager.

Under Simulation Mode, choose Real-time then click Ok OK.Image Removed

...

By clicking Simulation > Start in the HYPERSIM® HYPERSIM toolbar, the tasks are mapped automatically to the various cores, the code is compiled and the simulation starts running.

...

Once it is started, the Start button is grayed out and the Stop button is available to stop the simulation.