Table of Contents | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
...
HYPERSIM 2024.1.3
Software Toolboxes Installed with HYPERSIM
Toolbox | Version |
---|---|
v2.17.1.xx |
I/O Interfaces
Added support for slot types C and D mezzanine.
FPGA-Based Power Electronics Toolbox
eHS Blockset
Include Page | ||||
---|---|---|---|---|
|
...
HYPERSIM 2024.1.0
Software Toolboxes Installed with HYPERSIM
Toolbox | Version |
---|---|
v2.16.2.35 |
Added
Added support for MATLAB R2023b
Added a “format” column in the sensor view that displays the format of a signal value such as “double” or “int”
Added a Diagnostic Button in the Help section that gathers relevant log files into a ZIP archive
Added numbered prefixes for coefficients in the mask of Transfer Functions
Added a warning upon opening OPAL-RT dashboards when the network configuration of the target does not support usage of graph widgets
Added an option in the Preferences menu to automatically add missing targets when opening a model
Added an option to save a license request into a JSON or TXT file allowing one to manually send it later in case the license server is not reachable
...
Added support for PSSE v35
Added support for new components:
Gas turbine governor (GAST)
SEXS
Improved the HYPERSIM console display of non-mapped components during import
Improved import logs with simplified information
Improved load flow handling through replacing
Sbase
withPgen
of machine for the base power of the ideal transformer when machines are connected on the same busImproved the descriptions of the import options
Fixed division-by-zero issue when
P=Q=0
for Switched ShuntsFixed issue when machine controls were not properly excluded when their associated machines were excluded
Removed
Pref
from HYGOV import
I/O Interfaces
Modbus Slave
Added an option to allow read/write operations on multiple coils and registers even if there are gaps between the address ranges
FPGA-Based Power Electronics Toolbox
eHS Blockset
Added a reset pin in the FPGA-Based Circuit component
Removed the parameter_set_id pin
Support 3-level NPC in eHS Gen5
Support 3-level T-Type in eHS Gen5
Support FD Line in the Schematic Editor workflow
Support x16 Licence class in the Schematic Editor workflow
Improve error management for license checking in S-function driver and support of High Performance licence for eHS Gen4
Support new License key EHS_CORE_TOKEN to replace the EHS_TOTAL_PERFORMANCE key. Backward compatible with previous licenses.
Support new License key EHS_MACHINE_CORE_TOKEN to limit the number of machine in use. Backward compatible with previous licenses.
Support OP5369 cards in the OP5700-OP5600 official firmware
Display Schematic Editor model version in eHS CPU Block
Display eHS Licence class in eHS CPU Block
Fix encoder number of pole pairs for Generic Machine (EFSTT-1813)
Fix to use SFP in ports in firmware without AI (EFS-7015)
Fix State initial conditions of capacitor initial voltage and inductor initial current (EFS-7029)
Fix Schematic Editor to allow negative values for 2 and 3 Winding Mutual Inductance(SCHEDITT-484)