Documentation Home Page HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Next »

NameDescription

21 - MHO Distance Relay

This block models a generic MHO phase distance element with 2 protection zones. 
25 - Synchronism-Check RelayThis block models a generic 25 synchronism-check or sync-check relay. 

27 - Undervoltage Relay

The under-voltage relay (27) operates when the voltage it monitors falls below a set of threshold values. 

27 - Undervoltage Relay (1-ph)

This component is a single phase under-voltage (27) relay with voltage magnitude as the input.

40Q - Loss-of-Excitation Relay

The Var-type loss-of-excitation relay (40Q) operates when the reactive power that a synchronous generator consumes from the system exceeds the threshold. 

49M - Thermal Overload Protection for Motors

This block models a 49M - Thermal overload protection function for motors.

50-51 - Overcurrent Relay

This relay comprises functionalities of the 50P (instantaneous or definite-time), 51P (inverse-time) and 51G (inverse-time) elements. 

50 - Instantaneous or Definite Time Overcurrent Relay (1-ph)

This component is a instantaneous or definite time overcurrent (50P) relay with current magnitude as the input.
50BF - Breaker Failure ProtectionThis relay detects a breaker failure to operate during fault and thus issues a back-up trip command to adjacent circuit breakers.
51 - Inverse Time Overcurrent (1-ph)This component is a single phase inverse time overcurrent (51P) relay with current magnitude as the input.

59 - Overvoltage Relay

The over-voltage relay (59) operates when the voltage it monitors exceeds a set of threshold values. 

59 - Overvoltage Relay (1-ph)

This component is a single phase overvoltage (59) relay with voltage magnitude as the input.
67 - Directional Overcurrent RelayThe directional overcurrent relay (50-51-67) trips if and only if the fault current magnitude is above the threshold (50-51) and it is in a specific direction (67). 
67 - Directional Relay Based on ImpedanceThe 67 directional relay can detect the direction of the input current using impedance and torque which are calculated for their respective elements.
79 - Auto recloserThis relay issues a close breaker command in a power system to restore services after a transient line fault.

81 - Frequency Relay

This frequency relay (81) includes three types of frequency elements, namely the overfrequency (81O), the under-frequency (81U) and the rate-of-change-of-frequency (ROCOF) (81R) elements. 

87T - Transformer Differential Relay

This model implements a transformer differential relay (87T) with harmonic restraint and harmonic blocking functions. 
  • No labels