Digital Inputs Configuration Page
This page is populated with a list of the Digital Input channels available for the selected Hardware Configuration.
The following configuration options are available at edit-time:
Digital Input Settings | |||
Enable PWM Measurement Channels | Enables the PWM Measurement feature for every Digital Input channel. When this option is enabled, an Advanced subsection is created under the Digital Inputs section and populated with DIXX Duty Cycle and DIXX Frequency channels as described in the table below. |
Digital Inputs Section Channels
This section includes the following custom device channels:
Channel Name | Type | Units | Default Value | Description |
---|---|---|---|---|
DIXX Duty Cycle | Output | Percent | 0% | Duty Cycle of the digital signal acquired on channel DI<XX>. Accuracy information can be found under PWM Measurement Accuracy. When Enable PWM Measurement Channels is enabled, the Digital Inputs >> Advanced >> Duty Cycle section is populated with one DIXX Frequency channel for each Digital Input channel. |
DIXX Frequency | Output | Hertz | 0Hz | Frequency of the digital signal acquired on channel DI<XX>. Accuracy information can be found under PWM Measurement Accuracy. When Enable PWM Measurement Channels is enabled, the Digital Inputs >> Advanced >> Frequency section is populated with one DIXX Frequency channel for each Digital Input channel. |
DIXX | Output | 0 | Digital data read by the FPGA on channel DI<XX>. The Digital Inputs section is populated with one DIXX channel for each Digital Input channel available in the selected Hardware Configuration. |