SCHEMATIC EDITOR WORKFLOW
In order to handle predictable mistakes, the FPGA Power Electronic Toolbox project provides a set of error messages displayed to the user.
Errors
CODE | DESCRIPTION | DISPLAY MESSAGE EXAMPLE |
---|---|---|
100 | No firmware has been selected in the Schematic Editor | Error (100): A firmware should be selected from the circuit editor simulator setup. |
101 | Too many scenarios on FPGA (parameter sets) | Error (101): Number of scenarios used on FPGA (6) exceeds the maximum supported for this circuit (5). To support more scenarios use option "use CPU to store and load scenario" |
102 | Empty model | Error (102): The model is empty. Please provide some inputs. |
103 | No measurements in the model | Error (103): Circuit should contain at least one measurement to be usable. |
104 | Disjoint circuit | Error (104): The model shall not be composed of two disjoint circuits. Circuits composed of multiple separated sub-circuits are not supported. |
105 | Too many sources | Error (105): The number of sources exceeds the limit supported by eHS Gen4 x16. The maximum number of sources allowed in the circuit is 16. |
106 | Too many switches | Error (106): The number of switches exceeds the limit supported by eHS Gen4 x16.The maximum number of switches allowed in the circuit is 24. |
107 | Too many measurements | Error (107): The number of measurements exceeds the limit supported by eHS Gen4 x16. The maximum number of measurements allowed in the circuit is 16. |
108 | Too many states | Error (108): The number of states exceeds the limit supported by eHS Gen4 x16. The maximum number of electrical states allowed in the circuit is 80. |
109 | Too many machines | Error (109): The maximum number of PMSM DQ supported is exceeded in the schema. For the selected firmware, only a maximum of 2 PMSM DQ is allowed. |
110 | Wrong file extension for VDQ | Error (110): Unsupported resource file extension: jpeg. Variable DQ only supports JMAG (.rtt) and ANSYS (.txt) formats. |
111 | Machine resolver external excitation parameters mismatch in the Schematic Editor | Error (111): The machine 'scim1' has its parameter Excitation Type assigned to external but no Analog Input has been assigned to the parameter Excitation Source. |
112 | No resource file found for a machine in VDQ or SH mode | Error (112): The component 'pmsm1' parameter Resource File cannot be found. Please provide some input in the "Motor Configuration" field in the Schematic Editor model. |
113 | BLDC not supported with the selected firmware | Error (113): The current version of the firmware does not support the BLDC machine. |
114 | Firmware resource not found | Error (114): The model configuration requires a firmware resource of type PMSM / BLDC, but none was found in the selected firmware VC707_2-EX-0001-3_2_8_621-eHSx128_Gen4_PMSMSH_IOConfig1-03-04. |
115 | Too many CPU driven gates | Error(115): The number of gates driven via the CPU exceeds the limit supported with the selected firmware. The maximum number of gates driven via the CPU allowed in the circuit is 72. |
116 | Missing parameters in the PMSM VDQ configuration file | Error (116): Error parsing the PMSM VDQ configuration file. Please update your file, following parameters are missing: DqTransformAngleOffset. |
117 | Negative time step for eHS | Error(117): The time step of eHS must be positive, but '-3.26' was found. |
118 | User time step is too small | Error(118): Unable to achieve the requested user time step of 200 ns. The minimum achievable time step for this circuit is 210 ns. (eHS cannot achieve the desired time step). |
119 | User time step is too big | Error(119): Unable to achieve the requested user time step of 4000 ns. The minimum achievable time step for this circuit is 2500 ns. (eHS cannot achieve the desired time step). |
120 | Circuit with a 'PMSM Spatial Harmonics' block requires a time step (Ts) multiple of 50 ns | Error(120): Circuit with a 'PMSM Spatial Harmonics' block requires a time step (Ts) multiple of 50 ns. |
121 | Too many AC sources | Error (121): The number of AC sources (40) exceeds the supported limit. For the selected firmware, only a maximum of 32 AC sources are allowed. |
122 | Circuit too large | Error (122): The circuit exceeds the number of computation unit available. Try to reduce the number of inputs, outputs, measurements or find equivalent circuit for group of components. |
123 | Circuit validation error | Error (123): The circuit validation has failed. Errors during circuit analysis: |
124 | Unsupported component | Error (124): Unsupported component sw1 (SW) with eHS Gen 5 solver. |
125 | User time step is not multiple of the FPGA clock period | Error (125): Model time step specified in the Schematic Editor (206ns) should be a multiple of the FPGA clock period (5ns). |
126 | Unsupported firmware license class | Error (126): Unsupported firmware license class for eHS Gen5: x64. |
127 | Not enough states | Error (127): No state found in the circuit. Circuit should contain at least one state (Inductor, Capacitor, Transformer). |
128 | Incompatible Version | Error (128): The Schematic Editor version 2.8.3 in use is not compatible with eFPGASIM version 2.9.1. Please install Schematic Editor version 2.9.1 or higher. |
129 | Incompatible Solver Settings | Error (129): The selected solver settings Analysis Method Nodal Analysis(eHS Gen 4) is not compatible with the firmware VC707_2-EX-0001-3_3_1_790-eHSx128_Gen5_IOConfig1-F5-4E. |
130 | Firmware Unavailable | Error (130): The model being imported uses a firmware that is not available. Please import the missing .ioconf file inside the Schematic Editor. |
131 | Database Unavailable | Error (131): OPAL-RT Unified Database is unavailable. Please verify your Schematic Editor installation. |
132 | Too many non-linear components | Error (132): The number of non-linear components (70) exceeds the supported limit. Only a maximum of 64 are allowed. |
133 | Invalid parameters for Surge Arrester | Error (133): Surge arrester sa1 has invalid parameters (it must have k2 > k1, k2 > k3 and alpha1 > alpha2 > alpha3). |
134 | Invalid Parameter Value compare to the Bounding Value | Error (134): The value v1 of the parameter p1 is invalid. The value must be (greater than or equal to | greater than | less than or equal to | less than) to v2. |
135 | Integer Type Parameter Value | Error (135): The value v1 of the parameter p1 is invalid. The value must be an integer. |
136 | Unsupported scenarios for such a big circuit | Error (136): The circuit size exceeds the number of computation unit available to support multiple scenarios (529/512). |
137 | Invalid table parameters | Error (137): The values for parameter IV Table voltages values are invalid. The values need to be strictly monotonically increasing. Please refer to page "Surge Arrester IV parameters file" in official documentation for further details. |
138 | Unsupported feature | Error (138): The feature Scenario from CPU is unsupported with current version 0.0.0 of eHS, needs 1.0.0 or higher. Update to a firmware which contains a newer version of the block to use this feature. |
139 | Malformed JSON | Error (139): Cannot read resource file, JSON file had following formatting issue: Unterminated array at line 1 column 23 path $.backEmfValues[1] |
140 | Ill-conditioned matrix | Error (140): Unable to process circuit with the specified parameters. Try to slightly change the relaxation parameter of the switches and try again. |
141 | Too many TSB switches | Error (141): The total number of switches added by Half Bridges (2) & Single Phase Cycloconverters (4) is 34 and exceeds the limit supported by eHS Gen 5 x128. The maximum number of Half Bridge & Single Phase Cycloconverter switches allowed in the circuit is 32. |
142 | Too many low latency measurements | Error (142): "The number of low latency external measurements (140) exceeds the limit supported by eHS Gen 5 x128. "+ "The maximum number of low latency external measurements allowed in the circuit is 128. Try to reduce the number of [Surge Arrester] components in your circuit." |
143 | Unable to evaluate expression | Error (143): A parameter has an expression value that could not be resolved.
|
144 | Outdated feature | Error (144): The feature "eHS Gen 5" has been improved and requires to update eHS Gen 5 to version 1.2.0. Update to a firmware which contains a newer version of the block to use this feature. |
145 | Unable to evaluate smallest Ts | Error (145): The Solver Strategy "Smallest Time Step" can't be apply on this circuit. Using the "Lowest Latency" strategy in the Schematic Editor will solve this issue but will increase the Time step of the circuit." |
146 | Model has unsaved changes | Error (146): The Schematic Editor model has unsaved changes. Save the model before loading the circuit. |