Connected I/O module is OP48H10 Fast I/O type H Module
Before designing cables, OPAL-RT recommends using the guideline Simulator EMC cable recommendations.
Before connecting the cables, make sure that the voltages or other electrical specifications are compatible with OPAL-RT DB37 specifications of I/O module OP48H10.
Connector P1 (top) | Do not connect to external power supply | Connector P2 (bottom) | ||||||
---|---|---|---|---|---|---|---|---|
DB37F Pin | Assignment | DB37F Pin | Assignment | DB37F Pin | Assignment | DB37F Pin | Assignment | |
1 | +DIO00 | 20 | GND | 1 | +DIO16 | 20 | GND | |
2 | +DIO01 | 21 | GND | 2 | +DIO17 | 21 | GND | |
3 | +DIO02 | 22 | GND | 3 | +DIO18 | 22 | GND | |
4 | +DIO03 | 23 | GND | 4 | +DIO19 | 23 | GND | |
5 | +DIO04 | 24 | GND | 5 | +DIO20 | 24 | GND | |
6 | +DIO05 | 25 | GND | 6 | +DIO21 | 25 | GND | |
7 | +DIO06 | 26 | GND | 7 | +DIO22 | 26 | GND | |
8 | +DIO07 | 27 | GND | 8 | +DIO23 | 27 | GND | |
9 | +DIO08 | 28 | GND | 9 | +DIO24 | 28 | GND | |
10 | +DIO09 | 29 | GND | 10 | +DIO25 | 29 | GND | |
11 | +DIO10 | 30 | GND | 11 | +DIO26 | 30 | GND | |
12 | +DIO11 | 31 | GND | 12 | +DIO27 | 31 | GND | |
13 | +DIO12 | 32 | GND | 13 | +DIO28 | 32 | GND | |
14 | +DIO13 | 33 | GND | 14 | +DIO29 | 33 | GND | |
15 | +DIO14 | 34 | GND | 15 | +DIO30 | 34 | GND | |
16 | +DIO15 | 35 | GND | 16 | +DIO31 | 35 | GND | |
17 | Reserved | 36 | GND | 17 | Reserved | 36 | GND | |
18 | Reserved | 37 | Reserved | 18 | Reserved | 37 | Reserved | |
19 | GND | 19 | GND |
The digital input/output threshold/level are configurable to TTL 5 V or 3.3 V using the OPAL-RT Boards configuration interface in RT-LAB or in the Block Parameters: Mezzanine Option Block in MATLAB/Simulink using S-Function blocks.
The OP48H10 32-channel digital IOs configured per 8-channel subsections to be used as digital inputs or digital outputs. The following table is a list of parameters to configure as input or output.
I/O MODULE OPTION BLOCK | ||
Parameters | CH00-07 / CH08-15 / CH16-23 / CH24-31 | |
Controller Name | 'OP4810 OpCtrl' | |
Mezzanine-type I/O module | ||
Direction | Input | Output |
Threshold low level (volt) | 0.8 V or 1.5 V* | 0.55 V |
Threshold high level (volt) | 2.0 V or 3.5 V* | 2.7 V or 4.3 V* |
* ttl 5v mode |
DIGITAL OUTPUT BLOCK PARAMETERS | ||||
Parameters | CH00-07 | CH08-15 | CH16-23 | CH24-31 |
Controller Name | 'OP4810 OpCtrl' | |||
Data In Port Number | 71 | 8 | 9 | 10 |
Number of channels | 8 | |||
Digital Output Type |
|
DIGITAL INPUT BLOCK PARAMETERS | ||||
Parameters | CH00-07 | CH08-15 | CH16-23 | CH24-31 |
Controller Name | 'OP810 OpCtrl' | |||
Data Out Port Number | 9 | 10 | 11 | 12 |
Number of channels | 8 | |||
Digital Input Type |
|
In addition to the parameters listed above, other parameters may need to be configured. More information on the Din and Dout parameters can be found here: OP48H10 Fast I/O type H Module.