Mask and Parameters
Snubber resistance | Snubber resistance value, only used in high impedance mode. |
---|
Snubber Capacitor | Snubber capacitor value, only used in high impedance mode. |
---|
Cell capacitor | Value of the cell's capacitor. |
---|
Resistance in shunt with the cell capacitor | Value of the discharge resistance for the cell's capacitor. |
---|
Initial capacitor voltage | The initial voltage value of the cell capacitor. It can be a scalar if all the capacitors start at the same value. If a vector the same length then the total number of cell is used, the voltage for each cell’s capacitor can be set. |
---|
Ron | The internal resistance of the selected device, in ohms. |
---|
Number of cells | This determines how many cells are connected in series. A maximum of 50 cells can be connected in series. If more then 50 cells are required, a second MMC_1P block needs to be connected in series. |
---|
Sample time | Time at which the capacitor voltage will be computed. |
---|
Keep cell short-circuit upon error | Check this box if the cell capacitor should remain to 0 when an error occurs. |
---|
Upper gate (double) | double signals that controlled the upper switch gates. This signal has to be a vector of the same length as the number of cells. A signal value of 1 indicates the switch is conducting, while a value of zero indicates the switch is OFF. |
---|
Lower gate (double) | double signals that controlled the lower switch gates. This signal has to be a vector of the same length as the number of cells. A signal value of 1 indicates the switch is conducting, while a value of zero indicates the switch is OFF. |
---|
Center (SPS) | Middle point of the cell. |
---|
Common (SPS) | Common point of the cell. |
---|
Outputs
Vc (double) | The voltage at the cell's capacitor, vector of same length then the number of cells. |
---|
Error (double) | Ouput 0 in normal operation and output 1 if a short-circuit occurs. When the “keep cell short-circuit upon error” is checked it will output the total number of short-circuited cells. |
---|
Characteristics
Direct Feedthrough | No |
---|
Sample Time | Parameter |
---|
Work Offline | Yes |
---|
Dimensionalized | Yes |
---|