Documentation Home Page RT-LAB Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Advanced | SIPZ

POWER AND IMPEDANCE – [SIPZ]
Compute the power, impedance, addition or subtraction of two signals for a given harmonic.
CATEGORY
SI5

DESCRIPTION
This function allows to compute the power, impedance, addition or subtraction of two signals for a given harmonic.
RESULT VARIABLES AND PARAMETERS

Module (m)Module (or amplitude) resulting from the operation specified for the harmonic multiplied by the absolute value of the factor.
Phase (a)Angle a (or phase) resulting from the operation specified for the harmonic. Value is between -180 and 180 degrees [°].
Since the module is multiplied by the absolute value of the factor, the phase is modified if the multiplying factor is negative. In this case, 180 degrees are added to the phase.
Phase 0-360 (a0)Angle a0 (or phase) resulting from the operation specified for the harmonic. Value is between 0 and 360 degrees [°].
Real (r)Real part r of the module and angle computed (m * cos(a)).
Imaginary (i)Imaginary part i of the module and angle computed (m * cos(a)). (m * sin(a)).
Signal_1First signal to analyze (voltage signal).
Factor_1Multiplying factor to use for all samples of signal 1.
Signal_2Second signal to analyze (current signal).
Factor_2Multiplying factor to use for all samples of signal 2.
FreqFundamental frequency of the signals in Hertz [Hz], normally computed with the sifreq function.
Harmonic numberNumber of harmonic to compute.
  • 0: DC;
  • 1: Fundamental;
  • 2: 2nd harmonic;
  • n: nth harmonic (max. 30).
OperationOperation to execute on the modules (or amplitudes) and angles of the required harmonic for each input signal. The modules and angles are first computed on the two input signals and then the specified operation is applied to these modules and angles. The defined operators are :
  • p : power;
  • / : impedance;
  • * : multiplication;
  • + : addition;
  • - : subtraction;
Begin_timeTime at which the analysis of a signal must start. This time is expressed in milliseconds [ms]. This value must be greater than 0 and lower than the duration of the test. The default value is 0.
End_time
  • Time at which the analysis of a signal must end. This time is expressed in milliseconds [ms]. The value of this time must be larger than the specified begin_time and smaller than the duration of the test. Use the “HUGE” value to specify the end of the test. The default value is HUGE.

The begin_time and end_time specified for the calculation of the harmonics must be the same as those used in the sifreq sequences to compute the fundamental frequency.

FactorMultiplying factor for the results generated by the function. The default value of the multiplying factor is 1.0 and has no effect on the results.

SYNTAX

[m, a, a0, r, i] = sipz(a, 1, b, 1, 60, 1, "p", 0, HUGE, 1)
CHARACTERISTICS
Data type support
Double Floating point
EXAMPLE
The first diagram shows how to compute the different powers (p): apparent, active and reactive.

The following diagram shows how to compute the different impedances (/): complex, resistance and reactance.

Finally, the next diagram shows the different formulas used with the operations allowed: power (p), impedance (/), addition (+), subtraction (-) and multiplication (*).

Let:

m1module of signal 1
m2module of signal 2
a1angle of signal 1
a2angle of signal 2

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323