Documentation Home Page RT-LAB Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Advanced | SIMXSOM1

INTEGRAL MAXIMUM – [SIMXSOM1]
Computes the absolute maximum of an integral, a mean or a RMS value on a specific part of a signal and in a window moving.
CATEGORY
SI5

DESCRIPTION
The function allows to compute the absolute maximum of an integral, a mean or a RMS value on a specific part of a signal and in a window moving over the input signal.
RESULT VARIABLES AND PARAMETERS

Algebraic MaximumMaximum of the input signal, multiplied by the factor.
Absolute MaximumAbsolute maximum of the input signal, multiplied by the factor.
SignalInput signal to perform analysis
Signal_PartPart of the signal on which the analysis is done (neg, pos, sig, abs). Here are the definitions for the four distinct parts of a signal:
Neg 

Only the negative values of the input signal are used for the calculations. The other values are considered to be null.

Pos

Only the positive values of the input signal are used for the calculations. The other values are considered to be null.

Sig

The original input signal is used for the calculations.

Abs

The calculations are done on the absolute value of the input signal.

ThresholdThreshold to reach in order to start analyzing the signals. This threshold value must be positive since the absolute value of the sample is compared to it. The samples which do not exceed this threshold are considered as null. If this threshold is null, all the samples are automatically considered.
Operation

Operation to execute on the signal in a window moving over it (int, moy, rms). The maximum of the integrals, means or RMS values are kept.

  • int: integral,
  • moy: mean,
  • rms: rms value.
Window_LengthTime in seconds [s] during which the window moves over the analyzed signal. This time in seconds is reduced to the time of the analysis (end_time – begin_time), if the window time specified is longer than the duration considered for the signal. This window time cannot be null.
Begin_timeTime at which the analysis of a signal must start. This time is expressed in milliseconds [ms]. This value must be greater than 0 and lower than the size of the acquisition buffer. The default value is 0.
End_timeTime at which the analysis of a signal must end. This time is expressed in milliseconds [ms]. The value of this time must be larger than the specified begin_time and smaller than the duration of the test. Use the “HUGE” value to specify the end of the test. The default value is HUGE.
FactorMultiplying factor for the results generated by the function. The default value of the multiplying factor is 1.0 and has no effect on the results.


SYNTAX

[alg_max, abs_max] = simxsom1( input, "sig", 0, "int", 1/60, 0, HUGE, 1 )
CHARACTERISTICS
Data type support
Double Floating point
EXAMPLE
In the following example, the function compute the absolute maximum of the integral of the sine wave over a moving window.

The following diagram shows the window moving over a signal based on the time specified for the window.

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323
Follow OPAL-RT: LinkedIn | Facebook | YouTube | X/Twitter