Documentation Home Page ◇ RT-LAB Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
Advanced | SIMXSOM1
INTEGRAL MAXIMUM – [SIMXSOM1]
Computes the absolute maximum of an integral, a mean or a RMS value on a specific part of a signal and in a window moving.
CATEGORY
SI5
DESCRIPTION
The function allows to compute the absolute maximum of an integral, a mean or a RMS value on a specific part of a signal and in a window moving over the input signal.
RESULT VARIABLES AND PARAMETERS
Algebraic Maximum | Maximum of the input signal, multiplied by the factor. |
Absolute Maximum | Absolute maximum of the input signal, multiplied by the factor. |
Signal | Input signal to perform analysis |
Signal_Part | Part of the signal on which the analysis is done (neg, pos, sig, abs). Here are the definitions for the four distinct parts of a signal: |
Neg | Only the negative values of the input signal are used for the calculations. The other values are considered to be null. |
Pos | Only the positive values of the input signal are used for the calculations. The other values are considered to be null. |
Sig | The original input signal is used for the calculations. |
Abs | The calculations are done on the absolute value of the input signal. |
Threshold | Threshold to reach in order to start analyzing the signals. This threshold value must be positive since the absolute value of the sample is compared to it. The samples which do not exceed this threshold are considered as null. If this threshold is null, all the samples are automatically considered. |
Operation | Operation to execute on the signal in a window moving over it (int, moy, rms). The maximum of the integrals, means or RMS values are kept.
|
Window_Length | Time in seconds [s] during which the window moves over the analyzed signal. This time in seconds is reduced to the time of the analysis (end_time – begin_time), if the window time specified is longer than the duration considered for the signal. This window time cannot be null. |
Begin_time | Time at which the analysis of a signal must start. This time is expressed in milliseconds [ms]. This value must be greater than 0 and lower than the size of the acquisition buffer. The default value is 0. |
End_time | Time at which the analysis of a signal must end. This time is expressed in milliseconds [ms]. The value of this time must be larger than the specified begin_time and smaller than the duration of the test. Use the “HUGE” value to specify the end of the test. The default value is HUGE. |
Factor | Multiplying factor for the results generated by the function. The default value of the multiplying factor is 1.0 and has no effect on the results. |
SYNTAX
[alg_max, abs_max] = simxsom1( input, "sig", 0, "int", 1/60, 0, HUGE, 1 )
CHARACTERISTICS
Data type support
Double Floating point
EXAMPLE
In the following example, the function compute the absolute maximum of the integral of the sine wave over a moving window.
The following diagram shows the window moving over a signal based on the time specified for the window.
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323
Follow OPAL-RT: LinkedIn | Facebook | YouTube | X/Twitter