Block
Mask
Description
The EnDat 2.2 Master Unpacking block receive the data from the DataIn block and recover all signals needed by the EnDat Master block. Signal concatenation and reordering is performed inside the block.
Parameters
This block has no parameters.
Inputs
DataIn | This port must be connected to one of the DataINi output ports of the DataIn block. |
DataInSOF | This prot must be connected to one of the SofINi output ports of the DataIn block. |
Outputs
Start | A pulse to start EnDat Transmission | |||||||||||||||
DIN | EnDat Parallel data. The data available here must contain the data to be transmitted to the EnDat encoder.
| |||||||||||||||
Freq_OEM_Value | OEM value to determine transmission frequency. Value lies between 2 and (2^11) -1. | |||||||||||||||
Freq_TST_Value | OEM value to determine the EnDat recovery time "TST". Value lies between 2 and (2^11) -1. | |||||||||||||||
PositionValueWidth | This port provides the width of the position value (max 48 bits). |
Characteristics and Limitations
This block has no specific characteristics or limitations.