Documentation Home Page HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Current »

Once the I/O interface has been configured as desired, the user will have to connect signals in the model to data points in the driver by using the designated HYPERSIM sensors. The driver's connectable points depend on the number of slaves and on the number of analog and digital inputs and outputs of each slave.

The following lists the driver connectable points for an input (analog, binary or double-bit binary) and an output (analog or binary).


Analog / binary inputs

Connection pointDirectionDescription
Analog input X, Binary input X or Double-bit binary input X (X being the number of the point in its related configuration list)From model to driverData value


Analog / binary outputs

Connection pointDirectionDescription
Analog output X or Binary output X (X being the number of the point in its related configuration list)From driver to modelData value
  • No labels