Mask and Parameters
General Parameters
Description | Use this field to add all kinds of information about the component |
Base primary/secondary/tertiary winding voltage (rmsLL) | Base value for PU conversion (kV). Voltage expressed in kV rms LL This base voltage and nominal voltage will change, if the corresponding winding connection switches between delta and Y. |
Base power (total) | Base value for PU conversion (MVA) |
Base frequency | Base value for PU conversion (Hz) |
Magnetization Impedance Parameters
- Rm: Equivalent resistance of iron losses of the magnetic circuit (Ω)
- Lm: Magnetization inductance (H)
Winding Parameters
Primary/secondary connection | Winding type
|
Tertiary connection | forced to Delta |
Voltage (rmsLL) | Rated voltage of the winding (kV) Y connections: Voltage expressed in kV rms LL Delta connections: Voltage expressed in kV rms LL |
R1, R2, R3 | Leakage resistance of the winding (Ω) |
L1, L2, L3 | Leakage inductance of the winding (H) |
Neutral Impedance Parameters
R1, R2 | Neutral resistance of the winding; only applies to Y ground (Ω) |
L1, L2 | Neutral inductance of the winding; only applies to Y ground (H) |
C1, C2 | Neutral capacitance of the winding; only applies to Y ground (F) |
Ports, Inputs, Outputs and Signals Available for Monitoring
Ports
Net_1 | Primary winding connection (supports only 3-phase connections) |
Net_2 | Secondary winding connection (supports only 3-phase connections) |
Net_N1 | Neutral connection for primary winding (supports only 1-phase connections) |
Net_N2 | Neutral connection for secondary winding (supports only 1-phase connections) |
Inputs
- None
Outputs
- None
Sensors
ILMAG(a,b,c) | Magnetization current for each phase (A) |
IPRIM(a,b,c) | Primary current for each phase (A) |
ISEC2(a,b,c) | Secondary current for each phase (A) |
ISEC3(a,b,c) | Tertiary current for each phase (A) |