Description

This device is an ideal switch controlled by a control signal. The model allows the user to control the ON/OFF the circuit based on the holding current.


Table of Contents

Mask and Parameters

NameDescriptionUnitVariable = {Possible Values}
Precision Valve model

Enable: Recalculation of the switch operation using the exact time between steps (in percentage of Ts) of the valve command

Disable: precision valve model not used



RsnubberSnubber resistanceOhm

{0,1e12}

CsnubberSnubber capacitanceF{0,1e12}
IminHolding currentA{0,1e12}
RopenSwitch open resistanceOhm{0,1e12}
RcloseSwitch close resistanceOhm{0,1e12}
Control TypeExternal (input pins) or External (input sensors from hardwarae)


Ports, Inputs, Outputs and Signals Available for Monitoring

Ports

NameDescription
Net_1Network connection; the "+" indicates the current measurement direction (supports only 3-phase connections)
Net_2Network connection (supports only 3-phase connections)

Inputs

NameDescription
DDelay used for precision valve. It is expressed as a fraction of time step
PBinary coded firing pulses. Bits 0,1,2: forward pulses of Phases A,B,C. For single phase only Phase A is used

Outputs

None

Sensors

NameDescriptionUnit
DDelay used for precision valve.
PBinary coded firing pulses
DelayExt12Time delay through external signals
CmdExt12Command signal through external signal
State12Switch status
Cmd12Switch command
ISwitch currentA
DelaySwitch delays

  • No labels