Documentation Home Page HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Current »


HYPERSIM

Added

  • Added functionality to keep device sensors upon renaming a device
  • Added driver core protection to avoid multiple reservations of the same core upon simulation start
  • Added new driver license mechanism based on total number of data points used by all drivers
  • Added Ok/Apply/Cancel buttons and removed Save/Exit menu items in I/O interfaces configuration tool
  • Added capability to remember window size in sensor view and set Data Logger as the default view
  • Added new license version. A new license file is required with version 6.1
  • Added I/O mode validation, no need to set the I/O sequencing (sendMode) for OpalBoards anymore
  • Added MegaBytes to the available data logger file size limits
  • Added validation of the remaining disk space before writing the data logging file
  • Added new protection relay library with functions 21, 27, 40Q, 50/51, 59, 81 and 87T
  • Added view filters and ability to remember customized view in Sensors form and Selected Summary window
  • Added Global Configuration dialog box in I/O interfaces configuration tool to set the I/O sequencing (sendMode) as well as other options
  • Added external control capability on "Dynamic load"
  • Added "3-winding, 1-ph" to Network Transformers library
  • Added "3-winding, 1-ph w/tap" and "2-winding, 1-ph w/tap" to Network Transformers library
  • Added engine log file for each circuit
  • Added validation of the remaining disk space before starting the simulation
  • Added ability to open data logging record files (OPREC files) in ScopeView directly from Windows
  • Added a Data Source Parameters panel to ScopeView for OPREC files, allowing for navigation through the record
  • Added ability to open OPREC files in ScopeView's file chooser and removed Data Logger tab
  • Added default prefix unit "mega" for PQ mode in parameters form
  • Added the possibility to optimize the mapping of the tasks manually
  • Added validation of the license integrity before installation on Windows
  • Added I/O interfaces configuration tool and updated Sensors form
  • Added Data Logger in Sensors form
  • Added DesignWorks API functions to Python API
  • Added support for reloading FPGA configuration at simulation startup
  • Added State-space example models for single-phase and three-phase systems
  • Added distance relay (21) permissive overreach transfer trip (POTT) TestView example model
  • Added support for MATLAB R2016b and R2017a
  • Added licensing on number of nodes
  • Added a warning when the selected target does not have a valid license
  • Added option to display license content in Windows activation tool
  • Added warning at 15 days of license end on Windows
  • Added tool to compare license content when updating a license on Windows
  • Added option to recover a backed-up license file on Windows
  • Added support for signed integer data for I/O sensors
  • Added handshake between simulation server and thread to improve behavior at simulation stop
  • Added Reset console button to View tab of the ribbon for the user to reopen or clear the model consoles
  • Added OP4510 to standard bitstreams - Traditional I/O (DO, DI, Single TSDO, Single TSDI)
  • Added support for bundle to bundle and pin to bundle connections to the Python API
  • Added support for auto-expanding subcircuit pages when importing an EDD
  • Added loadSensors function to Python API
  • Added support for resetting performance monitoring with the Python API
  • Added support for excluded devices when importing an EDD
  • Added new probes in the SIMOUT log to monitor simulation initialization and deinitialization timings
  • Added support for gcc compiler on Red Hat 32-bit
  • Added preference to enable and disable automatic insertion of Transceiver, ItoF and FtoI block; disabled by default
  • Added console windows to display simulation log (.SIMOUT file)

Improved

  • Improved I/O interfaces configuration tool Exit functionality with respect to asking user whether to save changes
  • Improved tooltips in Network Sources library
  • Improved transformers form by disabling accelerator option in Neutral impedance tab
  • Improved transformers tooltips
  • Improved OP4510 standard bitstream
  • Improved UCM documentation: added available global variables
  • Improved ScopeView documentation with more details on the various functions
  • Improved topology analysis report
  • Improved firewall checkbox behavior in the installer
  • Improved "Target output, digital 4" form
  • Improved API documentation
  • Improved "Synch. machine (thermal)" speed regulator diagram in the form
  • Improved "Decoupling element" form usability
  • Improved forms for transformers with tap changer and decoupling element
  • Improved form for 3-ph bus and 1-ph bus

Fixed

  • Fixed subcircuit mask corruption
  • Fixed many problems in the Sensors form causing loss of configuration
  • Fixed Hyperlink issue preventing code generation with MATLAB R2015a
  • Fixed some issues linked to the device rename functionality
  • Fixed LLC-12pulse form which was not displaying Input sensors for the Firing parameter
  • Fixed CustomView grid construction adding unnecessary spaces at the bottom that might be noticeable depending on the number of columns
  • Fixed issue occurring in Selected Summary window after a data point is renamed
  • Fixed host and target version check bypassed by the API
  • Fixed start/stop button greyed out incorrectly when setting a preference using the API
  • Fixed importing an example model not overwriting the entire example folder when it already exists
  • Fixed issue with multiple definitions of S-function with Hyperlink generated code
  • Fixed failed analysis with models having large attributes in subcircuits
  • Fixed inverted pins for secondary and tertiary on "Zigzag, phase-shifting" transformer
  • Fixed Windows language issue with TestView
  • Fixed issue with version switching on the simulator using the API
  • Fixed equation's result in form that would revert to former value when the simulation starts
  • Fixed execution process (Analyze/ Map Tasks/ Generate Code) that is repeated even when there's no modification to the circuit
  • Fixed simulation infinite loop when using a Hyperlink model in fixed time step that is less than the simulation time step
  • Fixed short CP line issue when automatically converting to PI line
  • Fixed error when trying to add a CustomView to a subcircuit and View directory is not created
  • Fixed ScopeView template sensor assignment for configuration 11
  • Fixed hydraulic turbine diagram and location of Turb_mod parameter in "Synch. machine (hydraulic)" form
  • Fixed acquisition for time step greater than 1 millisecond
  • Fixed "Dynamic Load" lower limit on Kq parameter
  • Fixed Hyperlink multiple time step code generation when there is a space character in the path
  • Fixed EDD importation tool: manual path input works without pressing Enter key and documentation is updated
  • Fixed EDD importation bug when folder name contains "EDD"
  • Fixed TestView hypExcel: Auto Import Data on Play not working
  • Fixed units and default values in Network Sources "AC I source, programmable" and "AC V source, programmable"
  • Fixed disappearing observable with "Circuit breaker, 1-ph" and 3-ph when analyzing network
  • Fixed "Dynamic load" equations displayed in the form
  • Fixed issue with Simulink multiple time step code generation
  • Fixed issue when taking large snapshots
  • Fixed issues with multiple time step code generation in Hyperlink
  • Fixed engine crash when the current source frequency is set to zero
  • Fixed protection on the analysis of an imported MATLAB multiple time step model with a wrong time step
  • Fixed EDD importation when unit contains a space character
  • Fixed Hyperlink multiple time step generation with MATLAB R2014b
  • Fixed parallel code generation producing a compilation error
  • Fixed issue with Runners monitoring never resetting
  • Fixed issue with switch version function on OPAL-RT kernel modules
  • Fixed cable/line data JavaScript error
  • Fixed ribbon that could stay disabled after modifying the design
  • Fixed acquisition error when simulation has a large time step
  • Fixed wrong text in Target output analog form

Removed

  • Removed controlled view option
  • Removed "PQ" group unit in "Decoupling element" form
  • Removed UCM unit limitation; it is now possible to enter any custom unit
  • Removed device "Decoupling transformer" from library

I/O Interfaces

C37.118 Master

  • Added support for configuration via GUI

C37.118 Slave

  • Added support for RTA simulation mode in Windows
  • Added timestamp initialization to system time when using local synchronization source

IEC 60870-5-104 Slave

  • Improved performance
  • Fixed random disconnection of TCP communication

IEC 61850

  • Added support for OPAL-RT Linux 64-bit
  • Added support for configuration via GUI
  • Added support for simulation bit
  • Added support for configuration through the I/O interfaces configuration tool
  • Added capability to manipulate the data integrity (loss of data, duplication, delay and more) of Sampled Values streams
  • Added "IEC 61850 data integrity" component to Control Power Tools library
  • Improved timing precision when transmission is synchronized by Oregano card
  • Fixed order of data attributes in GOOSE messages

IEC 62056 Master

  • Fixed documentation

OPAL-RT Boards

  • Added UI to configure the target analog and digital I/O

Synchronization

  • Added support for configuration via GUI
  • Added support of new profiles in PTP mode


  • No labels