Documentation Home Page HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Current »

The HYPERSIM Hyperline tools compute the RLC parameters of an overhead transmission line from its conductor characteristics and tower geometry.


When you click the Line Data in the HYPERVIEW, the GUI is displayed as shown in Figure 1–2

The default parameters are for a single-circuit three-phase line with two ground wires.

Enter your own line parameters in various sections:

DescriptionThe upper section where you enter general parameters (units, frequency, ground resistivity, and comments).
Line GeometryThe table of conductors specifying the line geometry and the conductor types (middle section).
Conductor and bundle characteristics The table of conductor types defining the conductor characteristics for each type (bottom section).
Line Data ReportReport the electrical parameters of the line computed by the program.
Hypersim LineYou can select the line type, name, transposed, or not and then apply line parameters to the HYPERSIM model selected.


New caseBegin a new case with all parameters set to zero.
Load

The open file supports two types of files.

  • One of type is a *.hld geometrical file that contains geometrical information.
  • The other type is EMPT file *.dat compatible.
  • A browser must be open for selecting the desired *.hld or *.dat file.
  • Load your line model.
SaveSaves your line data by generating a *.hld (hyperline data file) file that contains the geometrical information and the line data.
Compute DataComputes the line data, the results are shown in the Line Data Report.
InfoLoads the PDF help file.
UnitsIn the pull-down menu, select “SI” of “PU”.
Default ParametersLoads default parameter values.