Known Issues 1.0.0

  • CMDETT-47: SPI modes 1 and 2 for the ADBMS6815 and ADBMS6830 are inverted (to use mode 1, user should select mode 2, and to use mode 2 user should select mode 1).

  • CMDE-118: Disabling a device introduces a small delay in the SPI communication. As a result, it is not recommended to disable more than five consecutive devices. Consider alternating between enabled and disabled devices in the ring daisy chain if this is a concern.

  • CMDETT-26: When sending a register read command from SPI Master A to the LTC6811 or LTC6813, if the hex value of the first register after the command bits is greater than 0x7, a bit will be carried over to the command portion. This does not interfere with the registers' results.

  • CMDETT-29: The first cell over/under voltage read command sent to the ADBMS6830 or LTC6811 (RDSTATD and RDSTATB respectively) returns an incorrect value. Sending the command again returns the correct response.

 