Documentation Home Page ◇ eHS Toolbox Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
Benchmarks | Energy storage system
Model name | Energy storage system based on 20 T-type converters |
---|---|
Highlights | Coupling between two FPGAs using SFP (10 PCS per eHS-Gen5 solver) |
Model diagram |
|
Inputs (sources) | 2 dc-voltage sources (Inverter Mode) |
Switches | 120 switches (per eHS solver) |
Outputs (measurements) | Inverter voltage (3 per PCS) Inverter current (3 per PCS), PCC voltage (3), Load current (3) |
States (L, C, ...) | L (63), C (3 equivalent) |
Hardware | OP5700
|
Software |
|
Minimum license required | eHSx128 |
Minimum time-step | eHSx128 Standard: 2225 ns eHS High Performance: ns |
The details can be found here: Developing power conversion system benchmark for ESS applications - MMC Internal Use - OPAL-RT (atlassian.net)
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323