Benchmarks | Energy storage system

Documentation Home Page eHS Toolbox Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Benchmarks | Energy storage system

Model name

Energy storage system based on 20 T-type converters

Model name

Energy storage system based on 20 T-type converters

Highlights

Coupling between two FPGAs using SFP (10 PCS per eHS-Gen5 solver)

Model diagram

 

image-20240718-140549.png

 

Inputs (sources)

2 dc-voltage sources (Inverter Mode)

Switches

120 switches (per eHS solver)

Outputs (measurements)

Inverter voltage (3 per PCS) Inverter current (3 per PCS), PCC voltage (3), Load current (3)

States (L, C, ...)

L (63), C (3 equivalent)

Hardware

OP5700

  • FPGA: Virtex VC707_2

Software

  • Platform: RT-LAB or HYPERSIM

Minimum license required

eHSx128

Minimum time-step

eHSx128 Standard:  2225 ns

eHS High Performance:  ns

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323