This block provides a standard Machines to eHS Interface. It allows the user to route the output currents of the machines models to the inputs of the eHS using a user-defined configuration.


Mask


Inputs

Last: This input triggers the sampling of the serializer (the module will start streaming the data in the serial buses once this signal is received).

DualMotorVDQ_0: This input takes the output of the first PMSM.

DualMotorVDQ_1: This input takes the output of the second PMSM.

MotorIM_0: This input takes the output of the first induction Machine.

MotorIM_1: This input takes the output of the second induction Machine.

MotorIM_2: This input takes the output of the third induction Machine.

MotorIM_3: This input takes the output of the fourth induction Machine.

MotorSRM_0: This input takes the output of the first Switched Reluctance Machine.

MotorSRM_1: This input takes the output of the second Switched Reluctance Machine.


Outputs

PMSM Serial: This output is a FLWS frame to provide the outputs of the PMSMs models to the eHS.

IM Serial: This output is a FLWS frame to provide the outputs of the Induction Machines models to the eHS.

SRM Serial:This output is a FLWS frame to provide the outputs of the Switched Reluctance Machines models to the eHS.


If you require more information, please contact https://www.opal-rt.com/contact-technical-support/.