In order to run the examples provided by the eFPGASIM electrical machine library, the user must be equipped with one of the simulators below.
OP4815 Chassis (High End)
Application Scope
We recommend the use of the OP4815 for models requiring any of the followings:
- Up to 32 Analog I/O channels (Aout at 10 MSPS)
- Up to 64 bi-directional Digital I/O channels
- More than two similar electrical machines model required on a single FPGA
- Large converter topologies that need to be simulated on the FPGA (eHSx128 is required)
- More than four high-speed serials I/O links
Chassis Overview
Recommended I/O Module Configuration
Table 1 describes the standard I/O modules provides with the OP4815 simulators for testing machine controls. This configuration allows running the various off-the-shelf machines examples that come with eFPGASIM software.
Table 1: Standard I/O module configuration for OP4815 Chassis
P1-P2 (Section A) | P3 (Section B) | P4 (Section C) | Ext (Section A-B) | |
---|---|---|---|---|
Slot 1 | OP48H10 32 Digital Input Output channels | OP48H10 16 Analog Output channels 10 MSPS | OP48H10 16 Analog Inputs 5 MSPS | N/A |
Slot 2 | OP48H10 32 Digital Input Output channels | OP48H10 16 Analog Output channels 10 MSPS | OP48H10 16 Analog Inputs 5 MSPS | N/A |
Slot 3 (Extension) | N/A | N/A | N/A | RS422 TransceiverBase board |
Note: Custom I/O configuration for specific applications are available via service request.
OP5607/OP5707 Chassis (High End)
Application Scope
We recommend the use of the OP5707 / OP5607 for models requiring any of the followings:
- More than 32 Analog I/O channels
- More than 64 Digital I/O channels
- More than two similar electrical machines model required on a single FPGA
- Large converter topologies that need to be simulated on the FPGA (eHSx128 is required)
- Complex multi-core CPU simulation (more than 3 cores is required) used for simulating controls or large power system network
- More than four high-speed serials I/O links
Chassis Overview
Recommended I/O Module Configuration
Table 1 describes the standard I/O modules provides with the OP5607/OP5707 simulators for testing machine controls. This configuration allows running the various off-the-shelf machines examples that come with eFPGASIM software.
Table 1: Standard I/O module configuration for OP5607 / OP5707 Chassis
Section A | Section B | |
---|---|---|
Slot 1 | OP5330-3 16 Analog Output channels 1 MSPS | OP5340 16 Analog Inputs 500 KSPS |
Slot 2 | OP5353 32 Digital Input channels | OP5360-2 32 Digital Output channels |
Slot 3 | OP5330-3 16 Analog Output channels 1 MSPS | OP5330-3 16 Analog Output channels 1 MSPS |
Slot 4 | OP5353 32 Digital Input channels | OP5360-2 32 Digital Output channels |
Note: Custom I/O configuration for specific applications are available via service request.
OP4610 Chassis (Mid-Range)
Application Scope
We advise the use of this simulator for models requiring any of the following:
- Up to 32 Analog I/O channels
- Up to 64 Digital I/O channels
- Two electrical machines model on a single FPGA
- Large converter topologies that need to be simulated on the FPGA (eHSx128 is required)
- CPU simulation on up to 6 cores
- Up to four high-speed serial links
Chassis Overview
Recommended I/O Module Configuration
Table 2 describes the standard I/O modules provided with the OP4610 simulator for testing machine controls. This configuration allows running the various off-the-shelf machines examples that come with eFPGASIM software.
Table 2: Standard I/O module configuration for the OP4610 Chassis
Section A | Section B | |
---|---|---|
Slot 1 | OP5369 32 Digital Input/Output channels | OP5330-3 16 Analog Output channels 1MSPS |
Slot 2 | OP5342 16 Analog Inputs 2 MSPS | OP5330-3 16 Analog Output channels 1MSPS |
Extension slot | RS422 TransceiverBase board |
Note: Custom configuration I/O configuration for specific applications are available via service request.
OP4512 Chassis (Entry level)
Application Scope
We advise the use of this simulator for models requiring any of the following:
- Up to 32 Analog I/O channels
- Up to 64 Digital I/O channels
- Two electrical machines model on a single FPGA
- eHSx64 is sufficient to simulate the converter topology
- CPU simulation on up to 4 cores
- Up to four high-speed serial links
Chassis Overview
Recommended I/O Module Configuration
Table 3 describes the standard I/O modules provided with the OP4512 simulator for testing machine controls. This configuration allows running the various off-the-shelf machines examples that come with eFPGASIM software.
Table 3: Standard I/O module configuration for the OP4512 Chassis
Section A | Section B | |
---|---|---|
Slot 1 | OP5369 32 Digital Input/Output channels | OP5330-3 16 Analog Output channels 1MSPS |
Slot 2 | OP5342 16 Analog Inputs 2 MSPS | OP5330-3 16 Analog Output channels 1MSPS |
Extension slot | RS422 TransceiverBase board |
Note: Custom configuration I/O configuration for specific applications are available via service request.
OP4510 Chassis (Medium End)
Application Scope
We advise the use of this simulator for models requiring any of the following:
- Up to 32 Analog I/O channels
- Up to 64 Digital I/O channels
- Two electrical machines model on a single FPGA
- eHSx64 is sufficient to simulate the converter topology
- CPU simulation on up to 4 cores
- Up to four high-speed serial links
Chassis Overview
Recommended I/O Module Configuration
Table 4 describes the standard I/O modules provides with the OP4510 simulator for testing machine controls. This configuration allows running the various off-the-shelf machines examples that come with eFPGASIM software.
Table 4: Standard I/O module configuration for the OP4510 Chassis
Section A | Section B | |
---|---|---|
Slot 1 | OP5353 32 Digital Input channels | OP5360-2 32 Digital Output channels |
Slot 2 | OP5340 16 Analog Inputs 500KSPS | OP5330-3 16 Analog Output channels 1MSPS |
Extension slot | RS422 TransceiverBase board |
Note: Custom configuration I/O configuration for specific applications are available via service request.
OP4200 Chassis (Low End)
The OP4200 Chassis is not currently supported by the eFPGASIM electrical machine model packages.
Legacy Chassis Support and Retro-Compatibility
The OP5600 Virtex 6 and Spartan 3 based simulators, the OP4500 and earlier chassis generation are excluded from the hardware list supported by the machine package.