Documentation Home Page ◇ HIL2GO Main Menu
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
HIL2GO-200 - Test your System
Page Content
Your system was fully tested at the factory. However, you can execute the tests to check if all is functioning as expected and get familiar with RT-LAB and your system.
Execute a Simple Functional Test and Demo
For a simple functional test of your system, you can execute one of the model examples provided as demos.
For example, you can load and execute the “rtdemo1” demo model, which is a PID controller. This model does not use the I/Os of your system.
If this model is running as expected, you know that your system basic configuration is correct.
The procedure is explained in this page of the RT-LAB user documentation: https://opal-rt.atlassian.net/wiki/x/MoiPC
Execute the Integration Test Model (Loopback Test)
We provide you a project file containing the integration test model used to test your system in the factory.
Please refer to this page in the RT-LAB user documentation for details: https://opal-rt.atlassian.net/wiki/x/_QiPC
The project includes the bitstream you need to use in your models.
Download, on your PC, the project file below, that includes the integration test model file.
What Is the Integration Test Model (Loopback Test)
The integration test model is a loopback model that outputs digital or analog signals from the simulator DB37 I/Os connectors to the digital or analog input DB37 I/Os connectors.
Signal readouts are viewed through the scopes of the MATLAB Simulink console of the model.
To validate the model, each output connector (digital or analog) should be physically connected to the corresponding input connector in order to read the signals received.
They can be connected all at once, or one at the time.
Connect the I/O cables
Use the loopback flat ribbon cable IDC40 to DB37M and the loopback board DB37, 40 positions with Vuser. See this page.
Refer to these pages for more details
Your bundle I/O connectors are described here: HIL2GO-200 - OP4610XG I/O System
Connecting the I/O loopback kit is explained here: OP5707XG Installation and Configuration | Connecting the I/O Loopback Kit
Also read this knowledge base article : How to power the different DB37 boards for digital outputs
Use the Integration Test Model (Loopback Test)
Once the model downloaded, follow these instructions to use the model.
The main steps are described below. See this RT-LAB user documentation for details.
Also, don't forget to view our video tutorials RT-LAB - Real-Time Simulation Systems Fundamentals and register for your FREE online self-pace e-Learning courses.
Use the current workspace or use an existing workspace or create a new workspace in RT-LAB.
Import the integration project with the integration test model in RT-LAB:
Click File > Import
Select General > Existing Projects into Workspace
Choose Select archive file, then click the Browse button
Select the downloaded zip file and click Open, then click Finish
Build the integration test model:
In the “HIL2GO_200_integration_test” tree, click Models.
Right click on IO_test and select Simulation > Build configurations…
Select your target (simulator) in the drop-down list “Development Node: on OPAL-RT (x64-based)”
Click OK.
The model start building up. When done, the build log can be viewed under the Compilation tab in the bottom right panel.
Load the model.
Execute the model.
Use the MATLAB Simulink console to view signals and check if all the inputted signals corresponds to the outputted signals. See the sections below.
Din and Dout Loopback Test
Connect the loopback board to a Dout DB37 connector and connect the cable to a Din DB37
It is not mandatory to connect Vuser to a power source, but the Vuser Source switch must be set to “INT. 12V”
Observe the Dout feedback on the Din using the integration model
See the examples below.
Ain and Aout Loopback Test
Connect the loopback board to an Aout DB37 connector and connect the cable to an Ain DB37
Observe the Aout feedback on the Ain using the integration model.
See the example below
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323
Follow OPAL-RT: LinkedIn | Facebook | YouTube | X/Twitter