How to Modify Chassis ID on OP5607 OP5700 OP5707 OP5707XG

Introduction

The extended ID is only available for these models:

  • OP5607
  • OP5700
  • OP5707 / OP5707XG

The chassis ID may be composed in two parts and can be modified using BOTH DIP switches SW1 and SW6A.

DIP switches locations

Modify chassis ID with DIP switches SW1 and SW6A

DIP switch SW1:

  • Allows users to select LSB ID values (0-31)

DIP switch SW6A:

  • It allows users to select whether additional ID bits will be used in the chassis ID
  • Switch IND3 determines whether DIP switch SW6A is enabled [ON] or disabled [OFF].
  • If switch IND3 is ON, switches IND0, IND1 and IND2 will be used to complete the MSB chassis ID.


Example

This image provides an example of how to configure the chassis ID.