Description

The Route Mechanical Signals block is used to route the mechanical angles coming from the different machines to the resolvers / encoders modules available within the firmware. It can process up to 10 angles.


Mask


Inputs

LoadIn: This input is to configure the angle routing prior to the Real-Time Simulation. It has to be connected to a LoadIn port in asynchronous mode.

loadInSof: This port must be connected to the associated Start of Frame of the previous LoadIn.

Theta0-9: The angles represents the mechanical theta angles, in turn ratio, in UFix24_24 format, coming from the different machines.


Outputs

Out1,2: The Route Mechanical Signals outputs angles which are used as inputs for the first Resolver Encoder.

Out3,4: The Route Mechanical Signals outputs angles which are used as inputs for the second Resolver Encoder.


Characteristics and limitations

This block has no special characteristics.

Direct FeedthroughN/A
Discrete sample timeN/A
XHP supportN/A
Work offlineNO