OP4512 Certification and Standards

This product meets the essential requirements of applicable European Directives as follows:

The essential requirements of the directive 2014/30/EU are covered by the following harmonized standards:
EN61326-1 (2013) – Electrical equipment for measurement, control and laboratory use. The immunity test requirements used for this Product qualification are for the equipment intended to be used in an industrial electromagnetic environment.

 

Certifying Body

Standard Number

Standard Name

Specifications

Minimum performance requirement criteria

Certifying Body

Standard Number

Standard Name

Specifications

Minimum performance requirement criteria

FCC part 15 (2022), subpart B

Conducted Emissions

Class A 150 kHz-30MHz

 

FCC part 15 (2022), subpart B

Radiated Emissions

Class A 30 MHz-21GHz

 

image-20240115-144506.png

ICES-001 Issue 5 (2020)

Radiated Emissions

CSA CISPR 11:19 Group 1 - class A
30 MHz-1GHz

 

ICES-001 Issue 5 (2020)

Conducted Emissions

CSA CISPR 11:19 Group 1 - class A
150 kHz-30MHz

 

 

 

 

 

 

 

 

 

IEC61000-4-2 (2008)
 

Electrostatic Discharge Immunity

Contact: ±4 KV Air: ±2kV, ±4kV, ±8 KV

B

IEC61000-4-3 (2020)
 

Radiated Electromagnetic Field Immunity

80 MHz-1000MHz: 10 V/m
1.4 GHz-6 GHz: 3 V/m

A

IEC61000-4-4 (2012)

Electrical Fast Transient Immunity 

Power: ±2 KV/ 5 kHz & 100 kHz
I/ O Ports: ±1 KV/ 5 kHz & 100 kHz
Communication Ports: ±2 KV/ 5 kHz & 100 kHz

B

IEC61000-4-5 (2014) A1 (2017)
 

Surge Immunity

Power: ±2 KV L-PE, ±1 KV L-L
I/O Ports: N/A
Communication Ports: N/A

B

IEC61000-4-6 (2013)

Immunity to Conducted Disturbances,
Induced by Radio-Frequency Fields

Power: 3 V
I/O Ports: 3 V
Communication Ports: 3 V

A

IEC61000-4-8 (2009)

Power Frequency Magnetic Field Immunity 

Continuous Field: 30A/m, 50 Hz & 60 Hz

A

IEC61000-4-11 (2020)

Voltage Dips, Short Interruptions and
Voltage Variation Immunity on AC Input

Voltage dips:
0%Un during 1 cycle
40%Un during 10 cycles (at 50 Hz)
40%Un during 12 cycles (at 60 Hz)
70%Un during 25 cycles (at 50 Hz)
70%Un during 30 cycles (at 60 Hz)

Short interruptions:
0%Un during 250 cycles (at 50 Hz)
0%Un during 300 cycles (at 60 Hz)

 

B
C
C
C
C

 

C
C

IEC61010-1:2010,

IEC 61010-1:2010/AMD1:2016

Single fault condition
Protective Conductor Abnormal
Cooling Abnormal
Input
Durability Of Markings
Applied Force
Permissible Limits For Accessible Parts
Impedance Of Protective Bonding Test
Dielectric Voltage Withstand
Humidity Conditioning
Capacitor Discharge
Stability 10 Deg
7.5.2 Handle Strength Test
7.6 Rack Mounting Test
Static Rigidity
Impact
Drop (Non-Hand Held Equipment)
Temperature

4.4.1
4.4.2.3
4.4.2.10
5.1.3 c
5.3
6.2.2
6.3
6.5.2.4
6.8
6.8.2
6.10.3
7.4
7.5.2
7.6
8.2.1
8.2.2
8.3.1
10.1

 

 

 

 

 

 

 



  