Page Content
If the data is imported from PSS/E, CYME or PowerFactory, any new Modelica based component should be also registered in the corresponding mapping file.
The mapping files for PSS/E, CYME and PowerFactory are defined as PSSEv32_mapping.csv
, CYMEv7x_mapping.csv
and PFv2017_mapping.csv
respectively.
Mapping to PSS/E Parameters
To register a new component beside the existing ones in this file, the following fields must be filled:
ID | ID field used in the |
---|---|
Name | Name of the component as used in PSS/E DYR file. |
Number of Parameters | Number of Parameters field in |
Parameter indices | Indices which map data entries from RAW and DYR files to the corresponding parameters defined in |
In addition, some specific characters are used as follows to facilitate mapping data from RAW and DYR files:
! (exclamation mark) | Ignore parameters while reading the input file. |
---|---|
` (back-tick) | Hard-code the value of a parameter required for an FMU. |
Default | If the order of indices in DYR file is exactly the same as it is given in FMUGlossary.csv file. |
r# | To specify the indices of the data entry in the RAW file for generator components. As an example, the figure below shows an example of a generator data record in which the indices are shown in red. Assuming the GENCLS type machine for this generator, r2 and r3 should be inserted in the |
bvm# | For absolute bus voltage magnitude, bva# for bus voltage angle where # is the index of the power pin starting from 0. As an example, the figure below shows bus data record for bus no. 3, in which the voltage magnitude and voltage angle are also defined. Assuming a GENCLS type machine connected to this bus, keywords bvm0 and bva0 can be used in the |
---|
f | For nominal frequency. This information is located at the header of the RAW file. |
---|---|
sb | For Networks base power. This information is located at the header of the RAW file. |
Mapping to CYME Parameters [Disabled after v2020.4]
To register a new CYME component besides the existing ones in the CYMEv7x_mapping.csv
file, the following fields must be filled:
ID | Must be exactly the ID field used in the FMUGlossary.csv file. |
---|---|
Name | Must be the name of the component as used in CYME *.sxst file. |
Number of Parameters | Must be the same value as Number of Parameters field in FMUGlossary.csv file. |
Parameter Name | Must be the same name as the one defined for that component in the *.sxst file. |
In addition, some specific characters are used as follows to facilitate mapping data from *.sxst
files:
Use ! (exclamation mark) to ignore parameters while reading the input file.
Use ` (back-tick) to hard-code the value of a parameter required for an FMU.
Mapping to PowerFactory Parameters [Disabled after v2020.4]
To register a new PowerFactory component besides the existing ones in the PFv2017_mapping.csv
file, the following fields must be filled:
ID | Must be exactly the ID field used in the |
---|---|
Name | Must be the name of the component as used in PowerFactory |
Number of Parameters | Must be the same value as Number of Parameters field in |
Parameter Names | Must be the same name as the one defined for that component in the |
In addition, some specific characters are used as follows to facilitate mapping data from *.dgs
files:
Use ! (exclamation mark) to ignore parameters while reading the input file.
Use ` (back-tick) to hard-code the value of a parameter required for an FMU.