Description
This block implements a filter to select through a FLWS bus useful signals by filtering the input frame. These signals are flagged to increment a local generated address following the number of input selected.
The block send each data, valid and last for each selected signal and the local address generated.
Inputs
Input Data (DataIn) : This input must be a XFloat_8_24 signal. It receives the input data signal to be filter.
Input Valid (ValidIn) : This input must be a Bool signal. It receives the input valid signal to be filter.
Input Last (LastIn) : This input must be a Bool signal. It receives the input last signal to be filter.
Load In & Load In Sof (Load In & Load In Start Of Frame) : These load in ports is receive mapping, gain, offset and synchronization configuration from CPU.
Hard Reset : This input must be a Bool signal. It vehicles the hardreset of the model
Solver Reset : This input must be a Bool signal. It vehicles the reset from eHS.
Outputs
Output Data (DataOut) : This output must be a XFloat_8_24 signal. It sends to the output the data of the filtered signal.
Output Valid (ValidOut) : This output must be a Bool signal. It sends to the output the valid of the filtered signal.
Output Last (LastOut) : This output must be a Bool signal. It sends to the output the last of the filtered signal.
Output Address (AddrOut): This output send a local address generated from the number of signals previously filtered.
Reset: This output is the signal used to reset the block. If reset is applied, data coming out of the frame outport should be discarded.
Characteristics and limitations
Direct Feedthrough | NO |
Discrete sample time | YES |
XHP support | N/A |
Work offline | YES |
If you require more information, please contact https://www.opal-rt.com/contact-technical-support/.