Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Complete List of Changes in ARTEMiS 7.7.5

  • Compatibility with RT-LAB 2023.3

  • Improved offline simulation performance

  • Upgraded Wideband and Marti-FD line/cable gen-2 models

  • Removed obsolete models:

    • Artemis_HVDC_VSC_TSBhiZ

    • OpenPhase_SPS_PMSM_allModesR2011B

    • OpenPhase_SSN_PMSM_allModesR2011B

    • ThreeLevelInverter_IVIC_RTE2

    • adgrid03_SVC_ssn_scantest

    • art_power_transfosat

    • art_power_xfosaturable

    • artemis_ITVC_ExtinctionZeroCrossing

    • artemis_ITVC_ExtinctionZeroCrossingSSN

    • artemis_OLTCregtransformer_stublines

    • ssn_triphaseline

    • SSN_Dual_IM_DFIMturnratioR2015a

    • TSBRD_2level_IO

    • ssn_WB2_3phase

  • Fixed failing models:

    • AD_DRIVE06_hiZ_TSB_STUBLINE

    • ssn_Kundur

    • ssn_Kundur_rtlab

    • ssn_basic_matrix_converter

    • ssn_matrix_converter

    • ssn_48pulse_STATCOM

    • ssn_48pulse_STATCOM_AE

    • ssn_48pulse_STATCOM_multirate

    • ssn_IEEE_37node_withPMU

    • JMAG_reference_SH_JMAG028

    • SSNArtRectifier_ParallelDrive_4b_3LNPC

    • SSNArtInverter_3LevelNPC

  • Removed obsolete blocks:

    • Asynchronous machine model with turn ratio (now standard in Simscape SimPowerSystems)

    • Three-Phase Fault block was superseded by the opElectricFault block of ARTEMiS

    • Switched core transformers models (now superseed by SSN OLTC models)

    • Simple Switched-segment MOV (now replaced by SSN iMOV model)

  • Added blocks inGrid Forming Control Library

  • Added example model

    • Distance protection relay

    • 505167 directional overcurrent protection relays

    • 87T protection relay

Complete List of Changes in ARTEMiS 7.7.4

  • Compatibility with RT-LAB 2023.2

New Features

Enhancements & Bug Fixes

  • Smart Inverter Library : fixed bug in Secondary control block 

  • Improved license check and license error messages 

  • Fixed marti_line and wideband lines for OPAL-RTLinux 

  • Fixed a compatibility issue during compilation of some TSB models 

  • Corrected the Voltage-Behind Reactance Synchronous Machine (VBR-SM) simulink block documentation

  • SSN code optimized to run offline correctly, with speed gain in line with theoretical expectations

  • Fixed SPS phasor simulation mode running with ARTEMiS installed

Deprecation and Removals

  • Matlab/Simulink R2018A, R2019A, R2019B : end of support

Complete List of Changes in ARTEMiS 7.7.3

  • Compatibility with RT-LAB 2023.1

New Features

  • New Smart Inverter Control Simulink Toolbox (IEEE Std. 1547‐2018) to perform Rapid Control Prototyping (RCP) of smart inverter

    controllers 

    controllers 

  • New SSN Nodal Inverter models. These blocks replace IVIC inverter blocks. Demos upgraded.

  • New ARTEMiS Variable PQ Load with Remote Calculation blocks. Improves the speed of large distribution grid demo by a factor 2 and more.

  • Added support for MATLAB version R2022a

Enhancements & Bug Fixes

  • Better performance on the new OPAL-RT hardware platforms ((Intel Xeon Scalable Processor based) by using vector processor instructions (AVX).

  • Upgraded Switched Reluctance Motor model.

  • 2-level TSB model compilation error (blob error) now fixed.

  • Updated version of ssn_TrainTractionDrive example model (fixed compilation error) and AD_DRIVE06 example models

  • Fixed simulation resetting automatically when enabling SSN

Known issues

  • FD-line (Marti-type) 2nd generation model does not compile correctly (Ref. SOLVTT-451). 

Deprecation and Removals

  • Matlab/Simulink R2015B, R2016A, R2016B, R2017A, R2017B : end of support

Complete List of Changes in ARTEMiS 7.7.2

  • Compatibility with RT-LAB 2022.1

New Features

  • New SSN Spatial-Harmonic-PMSM model compatible with JMAG and Maxwell data formats. The model is snubber-free.

  • New SSN  '1-port' (grounded) or '2-port' Parallel-RLC and Series-RLC blocks. Port number are user selectable. SSN RLC blocks allow for on-line parameter modifications.

  • New Smart Inverter library (beta)

  • Steady-state initialization in SSN for source and linear parts.

Enhancements & Bug Fixes

  • SSN-OLTC (v3) had a bug in code generation only. Fixed.

Complete List of Changes in ARTEMiS 7.7.1

  • Compatibility with RT-LAB 2021.3

New Features

  • New 5-level Neutral Point Clamped TSB-RD model and demo.

  • New Virtual Educational Laboratory demo page. Included laboratories: synchronous machine and induction machine.

  • New Machine models with constant admittance matrix. Can accelerate simulation by allowing prefactorization of the SSN admittance matrix.

Enhancements & Bug Fixes

  • All SSN custom models (Machines, RLC, etc...) are now fully linked to the library and runnable in this mode.

  • All SSN synchronous machine model optimization on the inductance inverse, now made separately in the d and q axes.

  • ArtEvents TSDOUT bug resolved: ports numbers were not in order (beta).

Complete List of Changes in ARTEMiS 7.7.0

  • Compatibility with RT-LAB 2021.2

New Features

  • Support of MATLAB versions R2020a and R2020b.

Enhancements & Bug Fixes

  • Correction to the SSN-PMSM motor model: works correctly now with the delayed speed term option.

  • Correction to the Banshee demo: added missing files required for execution in Simulink.

  • Correction to the standard SPS IGBT model: now works correctly in ARTEMiS.

  • ArtEvents PWM block now includes a phase shift option on the duty cycle for application with cascaded inverters with phase shifted carriers. (Beta)

  • New demo with 5-level NPC inverter using TSB-RD. Model name: TSB_RD_5levelNPC_Drive.slx (Beta)

  • Introductory Help page for the Opal-RT Machine Courseware.

  • Multirate stubline parameter modification for easier parametrization.

  • SSN-OLTC transformer parameter modification for easier parametrization.