Documentation Home Page OPAL-RT Dashboard Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Current »

Page Content

Known Issues & Limitations

  • Multi-user sessions are not supported.

  • OPAL-RT Dashboards only works with 64-bits targets (only OPAL-RTLinux 3 or Windows targets, not Red Hat nor CentOS).

  • No undo-redo.

  • No user authentication/session management.

  • Signal values can be visualized in Panels only, not in Tables.

  • Tab Group widgets are not supported by the Python API and the copy-paste.

RT-LAB 2024.4

  • Boolean data points are not visible in Dashboards.

  • Dashboards does not support block or parameter with accent.

HYPERSIM 2024.4

  • HYPERSIM unit system is not available in Dashboards.

  • Equality of multidimensional parameters in HYPERSIM cannot be enforced in Dashboards.

  • Dashboards may hide HYPERSIM pop-up error message.

RT-LAB 2024.3 (Additional limitation)

  • For projects with more than 30k data points, it is recommended to use the Python API to create panels and connect data points.

  • Launching multiple models at the same time may leads to data not appearing in graph widgets if data point share the same name.

HYPERSIM 2024.3 (Additional limitation)

  • For projects with more than 30k data points, it is recommended to use the Python API to create panels and connect data points.

  • If Analyze is done and the project is then closed without being saved at least once, connections between data points of HYPERSIM model with sub-circuits and widgets may be lost.

RT-LAB 2024.2 (Additional limitation)

  • Launching Graph Widgets on multiple Target is not supported.

  • The use of Dashboards in RT-LAB and HYPERSIM at the same time is not supported.

HYPERSIM 2024.2 (Additional limitation)

  • Launching Graph Widgets on multiple Target is not supported.

  • The use of Dashboards in RT-LAB and HYPERSIM at the same time is not supported.

RT-LAB 2024.1 (Additional limitation)

  • Error message “Dashboards seams unavailable” may appears at start of RT-LAB if Dashboards installation is not successful. An independent reinstallation of Dashboard is needed.

  • Launching multiple models at the same time may leads to data not appearing in graph widgets. To solve the issue, start the models sequentially.

HYPERSIM 2024.1 (Additional limitation)

  • Error message “Dashboards seams unavailable” may appears at start of HYPERSIM if Dashboards installation is not successful. An independent reinstallation of Dashboard is needed.

RT-LAB 2023.3 (Additional limitation)

  • Multi-dimensional parameters and signals not supported in Panels;

HYPERSIM 2023.3 (Additional limitation)

  • Multi-dimensional parameters and signals not supported in Panels;

  • Removing a sensor from the HYPERSIM sensors list does not remove it from the Dashboards list. If a connection exists between a widget and a removed sensor, the HYPERSIM simulation will not start until the connection is removed.

  • When a simulation started in Dashboards fails to launch in HYPERSIM, an internal message is shown in Dashboards and the model status can be desynchronized. Use the fetch button to resynchronize.

  • In the graph widget, visual horizontal shifting of value happens when:

    • The trigger condition is set to rising edge, the trigger level is positive and the X position is at 0%.

    • The trigger condition is set to falling edge, the trigger level is negative and the X position is at 0%.


    Setting the X position at any other value stops the horizontal shifting.

RT-LAB 2023.2 (Additional limitation)

  • Renaming Simulink models in RT-LAB may result in synchronization issues in Dashboards.

  • Once Opal One v1.2 is installed (RT-LAB or HYPERSIM 2023.2), reinstalling Opal One v1.0 (RT-LAB or HYPERSIM 2023.1) might break the compatibilities of Opal One v1.2. Reinstall Opal One v1.2 to solve the issue.

HYPERSIM 2023.2 (Additional limitation)

  • Once Opal One v1.2 is installed (RT-LAB or HYPERSIM 2023.2), reinstalling Opal One v1.0 (RT-LAB or HYPERSIM 2023.1) might break the compatibilities of Opal One v1.2. Reinstall Opal One v1.2 to solve the issue.

RT-LAB 2023.1 (Additional limitation)

  • No copy-cut-paste;

HYPERSIM 2023.1 (Additional limitations)

  • No copy-cut-paste;

  • Opening Dashboards for more than one HYPERSIM model may result in synchronization issues;

  • No labels