Documentation Home Page ◇ ePHASORSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
Extended logging and model validation
If EPHASOR_VALIDATORS
variable not set, input validation of the model will not be performed. This could potentially lead to crashes of the model / MATLAB due to duplicated component names or broken references.
Note: Running these validators for large-scale systems can add a significant time to initialization process.
Therefore, it is recommended to disable them after an initial validation has been successfully completed.
For offline simulations the user can get more detailed logs by setting these environment variables, either in RT-LAB UI or in Advanced systems settings of Windows:
Name | Allowed Values | Description |
---|---|---|
|
| Enable to generate a log file named after the network file. It includes a detailed information in case the inversion of the impedance matrix for a multiphase component fails. |
| A comma-separated list of the following validators:
| The The link validator checks for broken references in the model. E.g. transformer connected to a non-existing bus. |
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323