Name | Description | Unit | Variable = {Possible Values} |
---|
Connection Type | For shunt elements, three types of connections are available for three-phase connections: - Ground Y Connection: one end of the shunt RL element is connected to a bus and the other end to the ground.
- Floating Y Connection: one end of each RLC branch of the RLC element is connected to a phase at the end of the bus, while the other ends are connected together, but not to the ground.
- Delta Connection (or triangle): In the case of a Delta connection, the three RL branches of a three-phase element are Delta connected, and each top of the Delta is connected to a phase of the bus.
|
| |
R | Resistance value for each phase. | Ω |
|
L | Inductor value for each phase. | H |
|
Base Power | Total Base power. | MVA |
|
Base Voltage | Base voltage rms LL if the shunt inductor is connected to a 3-phase bus and rms LN is only one phase is connected. | kV |
|
Base Frequency | Base frequency. | Hz |
|
Enable User Initial Value |
|
|
|
Initial Current | Initial current, cannot be modified while the simulation is running. | A |
|