Description

Grounded inductor.



Table of Contents

Mask and Parameters

Name

Description

Unit

Variable = {Possible Values}

Name

Description

Unit

Variable = {Possible Values}

Connection Type

For shunt elements, three types of connections are available for three-phase connections:

  • Ground Y Connection: one end of the shunt RL element is connected to a bus and the other end to the ground.

  • Floating Y Connection: one end of each RLC branch of the RLC element is connected to a phase at the end of the bus, while the other ends are connected together, but not to the ground.

  • Delta Connection (or triangle): In the case of a Delta connection, the three RL branches of a three-phase element are Delta connected, and each top of the Delta is connected to a phase of the bus.



R

Resistance value for each phase.

Ω



L

Inductor value for each phase.

H



Base Power

Total Base power.

MVA



Base Voltage

Base voltage rms LL if the shunt inductor is connected to a 3-phase bus and rms LN is only one phase is connected.

kV



Base Frequency

Base frequency.

Hz



Enable User Initial Value







Initial Current

Initial current, cannot be modified while the simulation is running.

A