Documentation Home Page HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 6 Next »


HYPERSIM

Added

  • Added the ability to simultaneously run 2 or more instances of HYPERSIM on the host PC
  • Added a license for PSCAD Import available to all users
  • Added a license for PSS®E Import available to all users
  • Added a model to the Target Inputs and Outputs Library:
    • Target I/O Interface to help visualize and simplify the management of I/O connections in the schematic 
  • Added models to the Control Protection Relay Library:
  • Added new Example models:
    • Renewable Energy: MicroGrid Droop Control which demonstrates the Islanded Operation of an Inverter-based Microgrid Using a Droop Control Technique 
    • IO Interfaces: MuSE Example Project with the OP5033 which shows how MuSE can easily expand I/O capability by connecting multiple FPGA-based I/O expansion chassis
    • IO Interfaces: Added MMS Support and the IO Interface component to the IEC61850 Sync1588 Example Model
  • Added the following Python API commands:
    • getMonitoringValue which returns the current value of the specified, actively running Monitor Block
    • getMonitoringAllValues which returns the current value of all actively running Monitor Blocks
  • Added a new Warning for devices that are missing sensors 
  • Added a "Select/Deselect All" option for Record in Sensors Summary Form 
  • Added the ability to lock a model when a second user opens the same model when more than one instance of HYPERSIM is running
  • Added a Transformer Data tab in the Z-Based Transformer Parameter form that enables users to automatically generate parameters from manufacturer specifications 
  • Added FPGA details and a refresh button to the Target Information window that returns FPGA card type and Chassis ID 

Improved

  • Improved the simulation startup time for large models
  • Improved the Sensor Management workflow 
  • Improved Simulation Settings window with a cleaner interface, and additional information such as the Target Architecture
  • Improved error messages:
    • related to RPC timeouts by giving more specific information and additional details 
    • when a user attempts to start or apply a Target when the license (Host and/or Target) is invalid or missing 
  • Improved battery current measurement from bundle to output pin which will improve stability

Fixed

  • Fixed .oprec opening error when double-clicking on the file 

  • Fixed signal group returning to the default value when clicking on record in sensor summary view 

  • Fixed issue in Export Project Wizard where not all sensor configuration files were listed 
  • Fixed issue where localhost would sometimes not initialize due an IP address conflict 
  • Fixed naming of the output current and input voltage in the "Controlled V Source, series" to help address stability issues in models using this component

Removed

  • Removed Samba dependencies

  • Removed export as JPG in ScopeView (image export only supports *.png)

I/O Interfaces

General

  • Added jitter detection mechanism during idle time (hardware and software sync) 
  • Improved I/O Configuration UI:
    • Added filter columns on table of any configuration page 
    • Fixed reorder columns on any configuration page 
    • Removed the "Add above" button and simplified additions in lists by reducing insertion buttons to just 1 
  • Improved the handling time of large configurations 
  • Improved the configuration of the collapsed tree state following a refresh 

IEC 61850

  • Added a new I/O interface with support for IEC 61850 MMS protocol
  • Added conversion wizard to port legacy configuration and connections to the new interface
  • Fixed use on non-English Windows PCs
  • Fixed microsecond value placed in GOOSE packets when using the automatic clock detection mechanism

Modbus Master

  • Added the triggered read/write functionality 

  • Fixed byte ordering when reading float values 

OPAL-RT Board

  • Added support for new mezzanine OP5360-3
  • Added BETA support for new mezzanines OP5367-1, OP5367-3, OP5367-5
  • Fixed use of PWM Synchronize AIn (RCP) on OPALRT-Linux systems
  • Fixed TSDIN performance issues 
  • Fixed overruns occurring due to remotes not having output connections 
  • Fixed incompatibility between the Fast Scope FPGA and Default Output Values (DOV) features 
  • Fixed board ID validation issues for threshold (OP5369) and multi-rate (OP5030-#) configuration on remotes 

FPGA-Based Simulation

More detailed list of release notes are available at C:\OPAL-RT\eFPGASIM\v2.9.5.61\Docs\ReleaseNotes

  • Added support for ROff in all switch-based components
  • Added support for Solver settings, ability to select Node Analysis method and validate any circuit component compatibility
  • Added support for three new solver settings in eHS Gen5 : Discretization Method, Backward Euler and ART 5
  • Added support for 2MSPS sampling rate for analog outputs in standard firmware
  • Added support for initial state in capacitors and inductors in eHS Gen5
  • Added support for active low gate polarity in eHS Gen5
  • Fixed LCA in eHS Gen 4
  • Fixed resolver connection to external excitation in Generic Machine block


  • No labels