CMDE Add-on 1.0.1
Release Date
Jan 20, 2025
What’s New
Fixed CMDETT-96: Sleep bit not getting properly activated for the ADBMS6830.
Fixed CMDETT-56: Timing issue present at all hardware configurations between the emulated devices and DIOs, leading to SPI communication problems in hybrid setups (Real devices and emulated devices in the same ring).
Fixed CMDETT-71: LTC6810, LTC6811 and LTC6813 use two’s compliments representation for voltage measurements for simulations, which differs from the actual behavior of the real devices.
Fixed CMDETT-47: SPI modes 1 and 2 for the ADBMS6815 and ADBMS6830 are inverted (to use mode 1, user should select mode 2, and to use mode 2 user should select mode 1).
Fixed CMDETT-26: When sending a register read command from SPI Master A to the LTC6811 or LTC6813, if the hex value of the first register after the command bits is greater than 0x7, a bit will be carried over to the command portion. This does not interfere with the registers' results.
Upgrade Process
To migrate a VeriStand project to the latest version of the Cell Monitoring Device Emulation Add-On, please refer to the Project Migration Procedure.
NI Packages
This release installs the following NI Packages:
OPAL-RT Cell Monitoring Device Emulation 1.0.1
OPAL-RT Hardware Configuration Manager 3.0.1
OPAL-RT License Manager 2.7.0