Documentation Home Page ◇ Communication Protocols Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
IEEE C37.118 Master
Page Content
Have a question or need help?
Solution
Software Platform Compatibility
Product Selection Guide
C37.118 Master requires software license OP3272, which comes with 50 data points. Visit this page more information on data points.
If additional data points are required, then they may be added via product OP3050.
Since real-time simulators come with one available Ethernet port, if additional physical Ethernet ports are required on the real-time simulator, these can be added via a kit.
Note that for applications requiring many Ethernet ports, the OP4510 and OP4512 simulators are not recommended.
C37.118 Master can be added to real-time simulators without the need for additional hardware.
A time synchronization module to maintain high-precision sync and time-stamping may be required depending on the application. For more information on precision timing, please this page: Precision Timing Synchronization.
Type | Description | Product Number | Simulator Compatibility | |||
---|---|---|---|---|---|---|
OP4510v2 | OP5033XG | OP5600v2 | OP5700 | |||
Driver | Driver license for C37.118 Master protocol for PMU interface and synchrophasor communication. 50 I/O data points are included. For additional data points, add OP3050 (see below). | OP3272 | YES | YES | YES | YES |
Optional | License for additional I/O data points for Ethernet-based communication protocols. 1,000, 5,000, or 30,000 (unlimited) data points may be added. License OP3272 is required. | OP3050-1000 | YES | YES | YES | YES |
Optional | Dual-port PCIe X1 Gigabit Ethernet Kit for OP4xxx Series of Real-Time Simulators*. Can be added if more physical Ethernet ports are required. | OP3821 | OP4510v2 |
|
|
|
OP3821-4610 | OP4610XG |
|
|
| ||
Optional | Intel I350T4V2 Quad Port Ethernet Server Adapter 10/100/1000 Mbps for OP5xxx Series of Real-Time Simulators*. Can be added if more physical Ethernet ports are required. | I350T4V2BLK |
| YES | YES | YES |
Optional | Time synchronization kit with 0.1 ppm oscillator*. Supports IRIG-B, 1PPS, IEEE1588. For more information, including a full list of Precision Timing modules, visit the following page: Precision Timing Synchronization. | See here. | YES | YES | YES | YES |
* Available PCIe slot required. Note that OP4510 and OP4512 simulators only have one PCIe slot.
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323
Follow OPAL-RT: LinkedIn | Facebook | YouTube | X/Twitter