Documentation Home Page Hardware Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

OP8662-4/8 System Description

The OP8662 is a high voltage and current monitoring interface designed to be used with a real-time simulator (such as OP5600 or OP5700) to provide supplementary signal conditioning.
It is designed to be used either as a desktop (or shelf top) or installed in a standard 19-inch rack (2 Rack Unit) and uses standard connectors (DB37 and banana jacks) without the need for input/output adaptors, which makes connections for monitoring quick and easy.

The internal input conditioning modules, convert high current and high-voltage signals coming from the external device to ±10V or ± 12V voltage signals compatible with the real-time simulator's inputs.

The rear of the chassis provides the DB37 connector that links the OP8662 to the real-time simulator, while the front provides connectors (banana jack) for connecting client-side applications such as monitoring and measuring devices.

By installing the OP8662 as a link between the unit under test (ECU, motor controller, etc.) and the simulator as illustrated below, you can monitor the voltage and current on specific channels.

Features

  • 4 or 8 high-voltage probes and 4 or 8 high current probes
  • 4 mm banana jack measurement connectors at the front
  • DB37F connector at the rear for connection to the real-time simulator

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323