Documentation Home Page Hardware Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

OP8662-4/8 Front Interface

The OP8662 provides banana jacks to interface with monitoring devices.

OP8662-4-300 and OP8662-4-600

OP8662-8-300 and OP8662-8-600

APower switch and indicator
BGround connector
C

High current probe connectors (maximum 15 A AC), with red and green LEDs to indicate channel activity.

  • Green LED: "On" if there is activity on the channel, and "Off" if there is no activity on the channel.
    The LED will light up if it reads at least 5% of the maximum rated value, i.e., 0.75 A for all models
  • Red LED: Indicate an overcurrent on the channel.
    The LED will light up if it reads 105% or more of the maximum rated value, i.e. 15.75 A for all models.
D

High-voltage probe connectors (maximum 300 or 600 V), with red and green LEDs to indicate channel activity.

  • Green LED: "On" if there is activity on the channel, and "Off" if there is no activity on the channel.
    The LED will light up if it reads at least 5% of the maximum rated value, i.e.
    • 15 V for 300 V models
    • 30 V for 600 V models
  • Red LED: Indicate an overvoltage on the channel.
    The LED will light up if it reads 105% or more of the maximum rated value, i.e.
    • 315 V for 300 V models
    • 630 V for 600 V models

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323