Documentation Home Page Power Electronics Add-On for NI VeriStand Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Analog Inputs Section

Analog Inputs Configuration Page

This page is populated with a list of the Analog Input channels available for the selected Hardware Configuration. Gains, offsets, minimum and maximum saturation factors can be applied to the signals acquired using the analog input channels. 

The following configuration options are available at edit-time for each channel:

Analog Input Settings

Gain

Signal gain. The raw signal is multiplied by this value before the Offset, Min, and Max saturation are applied.

Offset

DC offset of the signal. This value is added after the Gain has been applied.

Min

Lower saturation limit of the signal. It is applied after the Gain and Offset.

Max

Upper saturation limit of the signal. It is applied after the Gain and Offset.

The following configuration options are available at edit-time and applied to all channels:

Analog Input Settings

Enable Gain and Offset as Channels

Enables execution-time updates of the signal gain and offset. When this option is enabled, an Advanced subsection is created under the Analog Inputs section and populated with ConnX.AIXX Gain and ConnX.AIXX Frequency custom device channels as described in the Channels table below.

Analog Inputs Section Channels

This section includes the following custom device channels:

Channel Name

Type

Units

Default Value

Description

Channel Name

Type

Units

Default Value

Description

AIXX

Output

Volts

0V

Raw analog data read by the FPGA on channel AI<XX>. The data has not been conditioned by the Gain, Offset, Min, and Max parameters. To view the conditioned signals at a higher resolution, consider using Waveforms instead.

The Analog Inputs section is populated with one ConnX.AIXX channel for each Analog Input channel available in the selected Hardware Configuration.

AIXX Gain

Input

 

Gain

Signal Gain to apply to channel ConnX.AI<XX>.

When Enable Gain and Offset as Channels is enabled, the Analog Inputs >> Advanced >> Gain section is populated with one ConnX.AIXX Gain channel for each Analog Input channel. The default value of this channel is the value of the Gain parameter in the Analog Inputs Configuration Page.

AIXX Offset

Input

Volts

Offset

DC Offset to apply to channel ConnX.AI<XX>.

When Enable Gain and Offset as Channels is enabled, the Analog Inputs >> Advanced >> Offset section is populated with one ConnX.AIXX Offset channel for each Analog Input channel. The default value of this channel is the value of the Offset parameter in the Analog Inputs Configuration Page.

Conditioned Analog Input signals can be mapped to other simulation components by navigating to their respective configuration pages listed below. Mapping options may vary between Hardware Configurations.

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323
Follow OPAL-RT: LinkedIn | Facebook | YouTube | X/Twitter