Documentation Home Page HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

ScopeView | Troubleshooting

 ScopeView is not connected to the right model
  1. In HYPERSIM, find the engine number related to your model.
  2. In the ScopeView Signals window, click “Data Source”, then “Load…”.
  3. In the HYPERSIM tab, select the engine number, the click "Load".

    If the list is not populated, click in the Host Name field and press "Enter", the list should populate itself.
  4. The data source will be updated and signals available.
 ScopeView is connected to the right model, but no signals are available in the list
  1. Make sure you've added some sensors or loaded a signal (.sig) file
  2. Make sure you've analyzed the network or started a simulation.
  3. One (1) and (2) have been executed, reload the data source.

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323