Documentation Home Page ◇ Hardware Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
OP8662-4/8 Rear Interface
A | Power plug and ON/OFF switch |
B | Chassis Earth. It must always be connected to the earth to avoid any possibility of electrocution or equipment damage. |
C | Fusebox. One fuse for internal power supply protection. Fuse reference is: fuse blade 3A 32V violet Cooper Bussmann # BK/ATC-3 (OPAL-RT Part Number T00-0673) |
D | DB37F I/O connectors (see OP8662-4/8 Pin Assignments for details). Only the top connector, labeled Ch I0-7/E0-7, is used. |
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323
Follow OPAL-RT: LinkedIn | Facebook | YouTube | X/Twitter