Documentation Home Page eHS Toolbox Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

V2.10 Kintex-7 410T - eHS x128 - Gen5 - IO Config2

OPAL-RT TECHNOLOGIES
1751 Richardson suite 1060, Montréal QC Canada H3K 1G6
www.opal-rt.com

© 2023 OPAL-RT TECHNOLOGIES All rights reserved

Legend

 SCHEMATIC EDITOR WORKFLOW

Introduction

This firmware includes:

  • One eHS x128 Gen5 Solver

  • One Analog Output Mapping and Rescaling (AOMR) module

  • One Analog Input Differential Rescaling (AIR) module

  • One Thermal Losses (TL) module

  • One Saturable Transformer (satXFO) module


LoadIn/DataIn/DataOut mapping


LoadIn

DataIn

DataOut

1

Config eHS

Inputs eHS

eHS Averaged

2

Scenario / Rst eHS = Status

TSDO 1 - eHS 0 to 7

eHS DownSample

3


TSDO 2 - eHS 8 to 15

Digital In 1A - 0 to 7

4

PWM 1A -  0 to 7

TSDO 3 - eHS 16 to 23

Digital In 1A - 8 to 15

5

PWM 1A -  8 to 15

TSDO 4 - eHS 24 to 31

Digital In 1A - 16 to 23

6

PWM 1A -  16 to 23

TSDO 5 - eHS 32 to 39

Digital In 1A - 24 to 31

7

PWM 1A -  24 to 31

TSDO 6 - eHS 40 to 47

Analog In 2A - 0 to 7

8


TSDO 7 - eHS 48 to 55

Analog In 2A - 8 to 15

9


TSDO 8 - eHS 56 to 63

eHS Period Averaged

10


TSDO 9 - eHS 64 to 71

eHS Period DownSample

11


Digital Out 1A - SDO 0 to 7

TimeOn Averaged

12

Config AOMR

Digital Out 1A - SDO 8 to 15

TimeOn DownSample

13

eHS PWM 1 - eHS 24 to 31

Digital Out 1A - SDO 16 to 23

Thermal Losses

14

eHS PWM 2 - eHS 0 to 7

Digital Out 1A - SDO 24 to 31


15

eHS PWM 3 - eHS 8 to 15



16

eHS PWM 4 - eHS 16 to 23



17

Config eHS AIR



18




19


AOMR/ Analog Out 1B -  0 to 7


20


Analog Out 1B -  8 to 15


21

Config Thermal Losses

Analog Out 2B -  0 to 7


22

SFP

Analog Out 2B -  8 to 15


23


eHS PWM 1 -  0 to 7


24


eHS PWM 2 -  8 to 15


25


eHS PWM 3 -  16 to 23


26


eHS PWM 4 -  24 to 31


27


eHS SWG


28




29




30




31




32




33


 Thermal Losses


34


SFP


System Overview


Extensive I/O compatibility (Polymorphism)

Listed cards are compatible at the same location

Digital In/Out Mezzanine

Compatible Mezzanine Modules

OP5369


Analog Out Mezzanine

Compatible Mezzanine Modules

OP5330-3 16 Aout

OP5330-1 16 Aout


Analog In Mezzanine

Compatible Mezzanine Modules

OP5340-1 16 Ain

OP5340-2 16 Ain 

Expansion Mezzanine

Compatible Mezzanine Modules

OP5969-1 DIN/DOUT RS422 5V

OP5969-2 DIN/DOUT FIBER OPTIC



eHS solver

SPS WORKFLOW SPECIFIC

Connectivity

SPS WORKFLOW SPECIFIC

Source Type

Source Index

Source Name

Details

Input

0

CPU Input


1

eHS Analog In

Slot 2A - Ch00-15

2

Data stream from SFP #00


3

Sine Wave Generator


4

Saturbale Transformer


Gate

0

Digital Input

Slot 1A - Ch00-31

1

PWM


2

CPU Gating Signal

TSDO 0-32

3

CPU Gating Signal

TSDO 0-32

SPS WORKFLOW SPECIFIC

To contextualize the Input and Gate Configuration table with this firmware configuration, the eHS firmware config tab must be configured with the following custom input source enumeration:

{'CPU Model',0,128;'Sine Wave Generator',3,32;'Analog In',1,16;'SFP',2,16;'Saturable Transformer',4,32}

And this custom gate sources enumeration:

{'CPU Model',2,32;'Digital Inputs',0,32;'PWM',1,32}

Thermal Losses module (TL)

SPS WORKFLOW SPECIFIC

There is one Thermal Losses tab in the eHS CPU block allowing to configure all four thermal models.

SPS Workflow - Thermal Losses (TL) block

Communication port configuration for the Thermal Losses (TL) block


Thermal Losses

Data In Port Number

33

Load In Port Number

21

Data Out Port Number

13


Analog Output Mapping and Rescaling module (AOMR)

AUTOMATIC AND NOT VISIBLE IN SCHEMATIC EDITOR WORKFLOW

There is one AOMR block allowing to configure all 32 analog outputs.

AOMR Master Subsystem (SM) block

Communication port configuration for the Analog Output Mapping and Rescaling (AOMR) block


AOMR - Slot 1B/2B

Version

V2

Data In Port Number

19

Load In Port Number

12


Analog Input Differential Rescaling module (AIR)

AUTOMATIC AND NOT VISIBLE IN SCHEMATIC EDITOR WORKFLOW

AIR block configures analog inputs for eHS.

AIR block

Communication port configuration for the Analog Input Differential Rescaling (AIR) block


AIR - Slot 2A

Channels

Ch00-15

Load In Port Number

17

AOMR Output

Lane Index

Signal Source

Details

0

eHS Outputs

eHS Y01-128

1

Data Stream from SFP #01



SFP Mapping and Communication Block

A total of 32 inputs and 32 outputs are available and configured using the SFP mapping and communication block.

Schematic Editor Workflow - SFP Mapping and Communication block


Communication port configuration for the SFP mapping and communication block


SFP - Channel 0

Data In Port Number

34

Load In Port Number

22


Analog In module (AI)

AI block reads signals from analog input channels on the simulator. 

SPS Workflow - AI block



Schematic Editor Workflow - OPAL-Board/AI

RT-LAB

HYPERSIM


Communication port configuration for the Analog Input (AI) block


Slot 2A 

Channels

Ch00-07

Ch08-15

Data Out Port Number

7

8

Connector Pin Assignment

Please refer to your hardware documentation

Hardware Pin assignment



Analog Out module (AO)

AO block configures analog output channels on the simulator. 

SPS Workflow - AO block


Schematic Editor Workflow - OPAL-Board/AO

RT-LAB

HYPERSIM


Communication port configuration for the Analog Output (AO) block


Slot 1B

Slot 2B

Channels

Ch00-07

Ch08-15

Ch00-07

Ch08-15

Data In Port Number

19

20

21

22

Connector Pin Assignment

Please refer to your hardware documentation

Hardware Pin assignment



Digital In module (DI)

DI block reads signals from digital input channels on the simulator. It could be static, TSDI or PWMIn.

SPS Workflow - DI block

Schematic Editor Workflow - OPAL-Board/DI

RT-LAB

HYPERSIM


Communication port configuration for the Digital Input (DI) block


Slot 1A 

Channels

Ch00-07

Ch08-15

Ch16-23

Ch24-31

Data Out Port Number

3

4

5

6

Connector Pin Assignment

Please refer to your hardware documentation

Hardware Pin assignment



Digital Out module (DO)

DO block configures digital output channels on the simulator. It could be static, TSDO or PWMOut.

SPS Workflow - DO block

Schematic Editor Workflow - OPAL-Board/DO

RT-LAB

HYPERSIM


Communication port configuration for the Digital Output (DO) block


Slot 1A 

Channels

Ch00-07

Ch08-15

Ch16-23

Ch24-31

Data In Port Number

11

12

13

14

Load In Port Number

4

5

6

7

Connector Pin Assignment

Please refer to your hardware documentation

Hardware Pin assignment

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323