Harmonic Analysis Using ScopeView

Documentation Home Page Courseware Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Harmonic Analysis Using ScopeView

List of Figures

  • Figure 1: Selection of ScopeView

  • Figure 2: Selection of function icon

  • Figure 3: Selection of Harmonic function

  • Figure 4: Selection of the signal

  • Figure 5: Selection of the number of Harmonics to read

  • Figure 6: Selection of Module and Phase

In order to plot the harmonic spectrum in ScopeVew you should follow these steps:

1- Run the model

2- Open ScopeView in HYPERSIM by pressing on the icon as follows:

image-20240710-204229.png
Figure 1: Selection of ScopeView

3- Select the function icon

image-20240710-204601.png
Figure 2: Selection of function icon

4- Select the Harmonic function

image-20240710-204753.png
Figure 3: Selection of Harmonic function

 

5- Choose the signal by clicking next to “signal” then choosing the name of the signal you want to read (Note that there are other signals if you change the selected signal type).

image-20240710-204952.png
Figure 4: Selection of the signal

6- Choose the Harmonics that you want to read for example 1:20 means you will read all harmonics from 1 to 20.

image-20240710-205313.png
Figure 5: Selection of the number of Harmonics to read

6- If you want to read both the module and the Phase select them both

image-20240710-205637.png
Figure 6: Selection of Module and Phase

7- Click on Add Function to add the function to ScopeView and be able to read the results like any other and then you are good to go.