Documentation Home Page ◇ eHS Toolbox Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
V2.19 Versal OP4815 - eHS x128 - Gen5 - PMSM - IO Config1
OPAL-RT TECHNOLOGIES
1751 Richardson suite 1060, Montréal QC Canada H3K 1G6
www.opal-rt.com
© 2023 OPAL-RT TECHNOLOGIES All rights reserved
Legend
SPS WORKFLOWSCHEMATIC EDITOR WORKFLOWSCHEMATIC EDITOR WORKFLOW WITH SFUNCTION
Introduction
This firmware includes:
- One eHS x128 Gen5 Solver
- Two Dual Permanent Magnet Synchronous Machines (PMSM-SH) models
- One Quad Generic Machines mode
- Two Analog Output Mapping and Rescaling (AOMR) module
LoadIn/DataIn/DataOut mapping
LoadIn | DataIn | DataOut | |
1 | Config eHS | Inputs eHS | eHS Averaged |
2 | Scenario / Rst eHS = Status | TSDO 1 - eHS 0 to 7 | eHS DownSample |
3 | TSDO 2 - eHS 8 to 15 | Digital In 1A - 0 to 7 | |
4 | PWM 1A - 0 to 7 | TSDO 3 - eHS 16 to 23 | Digital In 1A - 8 to 15 |
5 | PWM 1A - 8 to 15 | TSDO 4 - eHS 24 to 31 | Digital In 1A - 16 to 23 |
6 | PWM 1A - 16 to 23 | TSDO 5 - eHS 32 to 39 | Digital In 1A - 24 to 31 |
7 | PWM 1A - 24 to 31 | TSDO 6 - eHS 40 to 47 | Digital In 2A - 0 to 7 |
8 | PWM 2A - 0 to 7 | TSDO 7 - eHS 48 to 55 | Digital In 2A - 8 to 15 |
9 | PWM 2A - 8 to 15 | TSDO 8 - eHS 56 to 63 | Digital In 2A - 16 to 23 |
10 | PWM 2A - 16 to 23 | TSDO 9 - eHS 64 to 71 | Digital In 2A - 24 to 31 |
11 | PWM 2A - 24 to 31 | Digital Out 1A - SDO 0 to 7 | Analog In 1C - 0 to 7 |
12 | Config AOMR | Digital Out 1A - SDO 8 to 15 | Analog In 1C - 8 to 15 |
13 | eHS PWM 1 - eHS 0 to 7 | Digital Out 1A - SDO 16 to 23 | PMSM SH 1/2 |
14 | eHS PWM 2 - eHS 8 to 15 | Digital Out 1A - SDO 24 to 31 | PMSM SH 3/4 |
15 | eHS PWM 3 - eHS 16 to 23 | Digital Out 2A - SDO 0 to 7 | Quad Generic Machine |
16 | eHS PWM 4 - eHS 24 to 31 | Digital Out 2A - SDO 8 to 15 | RMS and Power calculation |
17 | Config AIR | Digital Out 2A - SDO 16 to 23 | Quadrature Encoder 1 |
18 | Config PMSM SH 1/2 | Digital Out 2A - SDO 24 to 31 | Analog In 2C - 0 to 7 |
19 | Config PMSM SH 3/4 | AOMR/Analog Out 1B 0 to 7 | Analog In 2C - 8 to 15 |
20 | Config Quad Generic Machine | Analog Out 1B 8 to 15 | eHS Period Averaged |
21 | Analog Out 2B 0 to 7 | eHS Period DownSample | |
22 | Config SFP | Analog Out 2B 8 to 15 | TimeOn Averaged |
23 | Config Lookup Table | eHS PWM 1 - 0 to 7 | TimeOn DownSample |
24 | RMS and Power Calculation | eHS PWM 2 - 8 to 15 | Quadrature Encoder 2 |
25 | Config Quadrature Encoder | eHS PWM 3 - 16 to 23 | Quadrature Encoder 3 |
26 | Config AOMR | eHS PWM 4 - 24 to 31 | Quadrature Encoder 4 |
27 | eHS SWG | ||
28 | PMSM VDQ 1/2 | ||
29 | PMSM VDQ 3/4 | ||
30 | Quad Generic Machine | ||
31 | AOMR 2A 0 to 7 | ||
32 | Quadrature Encoder | ||
33 | TSDO 10 - eHS 72 to 79 | ||
34 | TSDO 11 - eHS 80 to 87 | ||
35 | TSDO 12 - eHS 88 to 95 | ||
36 | TSDO 13 - eHS 96 to 103 | ||
37 | TSDO 14 - eHS 104 to 111 | ||
38 | TSDO 15 - eHS 112 to 119 | ||
39 | TSDO 16 - eHS 120 to 127 | ||
40 | TSDO 17 - eHS 128 to 135 | ||
41 | TSDO 18 - eHS 136 to 143 | ||
42 | SFP | ||
43 | Lookup Table Config |
System Overview
Permanent Magnet Synchronous Machine models (PMSM VDQ)
A total of two PMSM motors are available and configured using the Permanent Magent Synchronous Machine. The machine type could be Constant DQ, Variable DQ or BLDC.
Schematic Editor Workflow - PMSM (VDQ - BLDC) block
Communication port configuration for the Dual PMSM (VDQ) block
| Dual PMSM Motors VDQ | |
Machine Label | PMSM 1 | PMSM 2 |
Data In Port Number | 28 | |
Load In Port Number | 18 | |
Data Out Port Number | 13 |
| Dual PMSM Motors VDQ 2 | |
Machine Label | PMSM 3 | PMSM 4 |
Data In Port Number | 29 | |
Load In Port Number | 19 | |
Data Out Port Number | 14 |
Connectivity (Input)
Analog In - Slot 1C - Ch00-15
Encoder Output
Digital Out - Slot 1A/ Slot 3B - RS422
Encoder 1 | Encoder 2 | Encoder 3 | Encoder 4 | |
---|---|---|---|---|
A | Ch00 | Ch04 | Ch08 | Ch12 |
B | Ch01 | Ch05 | Ch09 | Ch13 |
Z | Ch02 | Ch06 | Ch10 | Ch14 |
Quad Generic Machine model (GM)
A total of four Induction Machines (IM) are available and configured using Generic Machine block in the eFPGAsim library.
Schematic Editor Workflow - Generic Machine block
SPS Workflow - Generic Machine block
SPS WORKFLOW SPECIFIC
Communication port configuration for the Quad Generic Machine (GM) block
| Quad Generic Machine | |||
Machine Label | IM 1 | IM 2 | IM 3 | IM 4 |
Data In Port Number | 30 | |||
Load In Port Number | 20 | |||
Data Out Port Number | 15 |
Connectivity (Input)
Analog In - Slot 1C - Ch00-15
Encoder Output
Digital Out - Slot 1A
Encoder 1 | Encoder 2 | |
---|---|---|
A | Ch00 | Ch04 |
B | Ch01 | Ch05 |
Z | Ch02 | Ch06 |
Power calculation module
SPS WORKFLOW SPECIFIC SCHEMATIC EDITOR WORKFLOW WITH SFUNCTION
RMS and power calculation for all circuit measurements is configured using the “Power Measurement Controller” block in the CPU model.
For more documentation on the block see : https://opal-rt.atlassian.net/wiki/spaces/PFPET/pages/65835684/CPU+Power+Measurement+Configuration+-+efs+Monitoring+cpuPowerBlock
Communication port configuration for the Power calculation block
RMS | |
---|---|
Load In Port Number | 24 |
Data Out Port Number | 16 |
Analog Output Mapping and Rescaling module (AOMR)
AUTOMATIC AND NOT VISIBLE IN SCHEMATIC EDITOR WORKFLOW
There is one AOMR block allowing to configure all 32 analog outputs.
AOMR Master Subsystem (SM) block
Communication port configuration for the Analog Output Mapping and Rescaling (AOMR) block
AOMR - Slot 1A | AOMR - Slot 2A | |
---|---|---|
Version | V2 | |
Data In Port Number | 19 | 31 |
Load In Port Number | 12 | 17 |
AOMR Output
Lane Index | Signal Source | Details |
---|---|---|
0 | eHS Outputs | eHS Y01-128 |
1 | PMSM SH 1/2 AnalogOut | Dual PMSM SH Model |
2 | PMSM SH 3/4 AnalogOut | |
3 | Generic Machine | |
4 | Data Stream from SFP #01 |
SFP Mapping and Communication Block
A total of 32 inputs and 32 outputs are available and configured using the SFP mapping and communication block.
Schematic Editor Workflow - SFP Mapping and Communication block
Communication port configuration for the SFP mapping and communication block
SFP - Channel 4 | |
---|---|
Data In Port Number | 42 |
Load In Port Number | 22 |
Analog In module (AI)
AI block reads signals from analog input channels on the simulator.
Schematic Editor Workflow - OPAL-Board/AI
RT-LAB
HYPERSIM
Communication port configuration for the Analog Input (AI) block
Slot 1C | ||
---|---|---|
Channels | Ch00-07 | Ch08-15 |
Data Out Port Number | 11 | 12 |
Slot 2C | ||
---|---|---|
Channels | Ch00-07 | Ch08-15 |
Data Out Port Number | 18 | 19 |
Connector Pin Assignment
Please refer to your hardware documentation
Analog Out module (AO)
AO block configures analog output channels on the simulator.
Schematic Editor Workflow - OPAL-Board/AO
RT-LAB
HYPERSIM
Communication port configuration for the Analog Output (AO) block
Slot 1B | Slot 2B | |||
---|---|---|---|---|
Channels | Ch00-07 | Ch08-15 | Ch00-07 | Ch08-15 |
Data In Port Number | 19 | 20 | 21 | 22 |
Connector Pin Assignment
Please refer to your hardware documentation
Digital In module (DI)
DI block reads signals from digital input channels on the simulator. It could be static, TSDI or PWMIn.
Schematic Editor Workflow - OPAL-Board/DI
RT-LAB
HYPERSIM
Communication port configuration for theDigital Input (DI) block
Slot 1A | Slot 2A | |||||||
---|---|---|---|---|---|---|---|---|
Channels | Ch00-07 | Ch08-15 | Ch16-23 | Ch24-31 | Ch00-07 | Ch08-15 | Ch16-23 | Ch24-31 |
Data Out Port Number | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
Connector Pin Assignment
Please refer to your hardware documentation
Digital Out module (DO)
DO block configures digital output channels on the simulator. It could be static, TSDO or PWMOut.
Schematic Editor Workflow - OPAL-Board/DO
RT-LAB
HYPERSIM
Communication port configuration for theDigital Output (DO) block
Slot 1A | Slot 2A | |||||||
---|---|---|---|---|---|---|---|---|
Channels | Ch00-07 | Ch08-15 | Ch16-23 | Ch24-31 | Ch00-07 | Ch08-15 | Ch16-23 | Ch24-31 |
Data In Port Number | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
Load In Port Number | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 |
Connector Pin Assignment