The following diagram and table illustrate the general cabling instructions for an OP8660 that is connected to third-party devices.

OP8660 Connectors


Connectors

Connector Type

Instructions

A

Inverter 1 and 2 (digital out)

DB9

Use the DB9 cable provided (113-0466) to connect the OP8660 to an IGBT drive or other devices that accept 0-5 digital pulses

B

Encoder 1 and 2

(differential digital in)

DB9

Use the DB9 cable provided (113-0668) to connect the OP8660 to a quadrature encoder (Max +/15V)

C

Analog inputs

Mini banana jack (2mm)

Use the cables provided (213-0100-0112, white and 213-0100-0113, yellow) to connect to an analog device.

D

Analog Outputs

Mini banana jack (2mm)

Use the cables provided (213-0100-0112, white and 213-0100-0113, yellow) to connect to an analog device.

E

Digital Inputs

Mini banana jack (2mm)

Use the cables provided (213-0100-0112, white and 213-0100-0113, yellow) to connect to a digital device.

F

Digital Outputs

Mini banana jack (2mm)

Use the cables provided (213-0100-0112, white and 213-0100-0113, yellow) to connect to a digital device.

G

High Current Measurements

Banana Jack (4mm)

Use the cables provided (211-0302-0009, yellow and 211-0302-0008, blue) to read the current on the channel (serial connection)

H

High Voltage Measurements

Banana Jack (4mm)

Use the cables provided (211-0302-0009, yellow and 211-0302-0008, blue) to read the voltage on the channel (parallel connection)