Documentation Home Page Hardware Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

OP5025XG Declaration of Conformity UKCA CE

Declaration of Conformity UKCA CE for the OP5025XG

  File Modified

PDF File OP5025XG-CE_UKCA_Declaration_of_Conformity-1V0.pdf

Mar 29, 2024 by Sylvain Ménard

Manufacturer Name/Address:

OPAL-RT Technologies Inc.
1751 Richardson suite 1060
Montreal, QC H3K 1G6 Canada
www.opal-rt.com 

This declaration of conformity is issued under the sole responsibility of: OPAL-RT Technologies Inc.

Product Model/Product

OP5025XG with any of the following options:

  • OP3411 (CAN kit)

  • OP5455 (Copper PCIe kit)

  • I350T4V2BLK (Ethernet)

Product Description

Simulator with optional communication cards intended for indoor use only.
Ratings: 100-240 VAC, 50-60 Hz, 400 W max, pollution degree 2

Product Category

Electrical equipment for measurement, control, and laboratory use.

CE Conformity with the Relevant Community Harmonization Legislation

  • 2014/30/EU – Electromagnetic Compatibility Directive

  • 2014/35/EU – Low Voltage Directive

  • 2011/65/EU & (EU) 2015/863 – Restriction of Hazardous Substances (RoHS) in Electrical and Electronic Equipment directive

  • 2012/19/EU – Waste from Electrical and Electronic Equipment (WEEE) Directive

UKCA Conformity with the Relevant Harmonization Legislation

  • Electromagnetic Compatibility Regulations 2016

  • Electrical Equipment (Safety) Regulations 2016

  • The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012

References to the standards in relation to which conformity is declared

References to the standards in relation to which conformity is declared

Category

Standards

Test Specifications

Emissions:

EN IEC 61326-1:2021

 

EN55011 (2016) A1 (2017)
CISPR11 (2015) A1 (2016) A2 (2019)

Conducted Emissions: Group 1 - class A 150 kHz-30 MHz
Radiated Emissions: Group 1 - class A 30 MHz-1 GHz, 1 GHz-20 GHz

Immunity:

IEC61000-4-2 (2008)

Contact: ±4 kV Air: ±2 kV, ±4 kV, ±8 kV

 

IEC61000-4-3 (2020)

80 MHz-1000MHz: 10 V/m
1.4GHz-6GHz: 3 V/m

 

IEC61000-4-4 (2012)

Power: ±2 kV / 5kHz & 100kHz
I/ O Ports: NA
I/ O Ports connected to power: ±1 kV / 5kHz & 100kHz

 

IEC61000-4-5 (2014) A1 (2017)

Power: ±2 kV L-PE / ±1 kV L-L
I/ O Ports: N/A
Communication Ports: N/A

 

IEC61000-4-6 (2013)

Power: 3 V
I/ O Ports: N/A
Communication Ports (Ethernet): 3 V

 

IEC61000-4-8 (2009)

Continuous Field: 30A/m - 50 Hz & 60 Hz

 

IEC61000-4-11 (2020)

Voltage dips:

0%Un during 1 cycle
40%Un during 10 cycles (at 50 Hz)
40%Un during 12 cycles (at 60 Hz)
70%Un during 25 cycles (at 50 Hz)
70%Un during 30 cycles (at 60 Hz)

Short interruptions:
0%Un during 250 cycles (at 50 Hz)
0%Un during 300 cycles (at 60 Hz)

Safety: