Documentation Home Page Hardware Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

OP4810-IO/OP4815-IO Declaration of Conformity UKCA CE

image-20240115-193241.png

Declaration of Conformity UKCA CE for the OP4810-IO and the OP4815-IO

  File Modified

PDF File OP481X-IO-CE_UKCA_Declaration_of_Conformity-1V0.pdf

Oct 24, 2024 by Sylvain Ménard

OPAL-RT Technologies Inc.
1751 Richardson suite 1060
Montréal, QC H3K 1G6 Canada
www.opal-rt.com 

This declaration of conformity is issued under the sole responsibility of: OPAL-RT Technologies Inc.

Product Model/Product

OP4810-IO/OP4815-IO with any of the following options:

  • OP48H10

  • OP48H20

  • OP5969-1

  • OP5969-2

Product Description

Simulator with Digital and Analog Input and Output cards intended for indoor use only.
Ratings: 100-240 VAC, 250 W max, pollution degree 2.

Product Category

Electrical equipment for measurement, control, and laboratory use.

CE Conformity with the Relevant Community Harmonization Legislation

  • 2014/30/EU - Electromagnetic Compatibility Directive

  • 2014/35/EU - Low Voltage Directive

  • 2011/65/EU & (EU) 2015/863 - Restriction of Hazardous Substances in Electrical and Electronic Equipment (RoHS) directive

  • 2012/19/EU - Waste from Electrical and Electronic Equipment (WEEE) Directive

UKCA Conformity with the Relevant Harmonization Legislation

  • Electromagnetic Compatibility Regulations 2016

  • Electrical Equipment (Safety) Regulations 2016

  • The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012

References to the standards in relation to which conformity is declared

References to the standards in relation to which conformity is declared

Category

Standards

Test Specifications

Emissions:

EN IEC 61326-1:2021

 

EN55011 (2016) A1(2017)
CISPR11 (2015) A1(2016) A2 (2019)

Conducted Emissions: Group 1 - class A 150 kHz-30 MHz
Radiated Emissions: Group 1 - class A 30 MHz-1 GHz, 1 GHz-20 GHz

Immunity:

IEC61000-4-2 (2008)

Contact: ±4 kV Air: ±2 kV, ±4 kV, ±8 kV

 

IEC61000-4-3 (2020)

80MHz-1000MHz: 10V/m
1.4GHz-6GHz: 3V/m

 

IEC61000-4-4 (2012)

Power: ±2 kV / 5 kHz & 100 kHz
I/O Ports: NA
I/O Ports connected to power: ±1 kV / 5 kHz & 100 kHz

 

IEC61000-4-5 (2014) A1(2017)

Power: ±2 kV L-PE / ±1 kV L-L
I/O Ports: N/A
Communication Ports: N/A

 

IEC61000-4-6 (2013)

Power: 3 V
I/O Ports: N/A
Communication Ports (Ethernet): 3 V

 

IEC61000-4-8 (2009)

Continuous Field: 30A/m - 50 Hz & 60 Hz

 

IEC61000-4-11 (2020)

Voltage dips:

0%Un during 1 cycle
40%Un during 10 cycles (at 50 Hz)
40%Un during 12 cycles (at 60 Hz)
70%Un during 25 cycles (at 50 Hz)
70%Un during 30 cycles (at 60 Hz)

Short interruptions:
0%Un during 250 cycles (at 50 Hz)
0%Un during 300 cycles (at 60 Hz)

Safety:

EN 61010-1:21010/A1:2019
IEC 61010-1:2010, IEC 61010-1:2010/AMD1:2016

Test procedure: CB Scheme

image-20240329-135445.png

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323