Documentation Home Page ◇ HIL2GO Main Menu
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
HIL2GO-100 - I/O Group 2, Section B (CH 00-15) - Analog Outputs (OP5330-3)
Connected I/O module is OP5330 - 16 Analog Output at 1 MSPS or 8 Analog Output at 2 MSPS
Before designing cables, OPAL-RT recommends using the guideline Simulator EMC cable recommendations.
Before connecting the cables, make sure that the voltages or other electrical specifications are compatible with OPAL-RT DB37 specifications of I/O module OP5330-3.
Connector P1 |
| |||
---|---|---|---|---|
DB37F Pin | Assignment | DB37F Pin | Assignment | |
1 | +AOUT00 | 20 | GND | |
2 | +AOUT01 | 21 | GND | |
3 | +AOUT02 | 22 | GND | |
4 | +AOUT03 | 23 | GND | |
5 | +AOUT04 | 24 | GND | |
6 | +AOUT05 | 25 | GND | |
7 | +AOUT06 | 26 | GND | |
8 | +AOUT07 | 27 | GND | |
9 | +AOUT08 | 28 | GND | |
10 | +AOUT09 | 29 | GND | |
11 | +AOUT10 | 30 | GND | |
12 | +AOUT11 | 31 | GND | |
13 | +AOUT12 | 32 | GND | |
14 | +AOUT13 | 33 | GND | |
15 | +AOUT14 | 34 | GND | |
16 | +AOUT15 | 35 | GND | |
17 | +12 V* | 36 | GND | |
18 | Not used | 37 | Not used | |
19 | Not used |
|
|
* Internally provided by the simulator. Non-isolated, limited to 400 mA.
Analog Output channels in this bitstream can be reserved by eHS and managed in OPAL-RT Schematic Editor.
ANALOGOUT BLOCK PARAMETERS | ||
Parameters | CH00-07 | CH08-15 |
Controller Name | 'OP4512 OpCtrl' | |
DataIn Port Number | 19 | 20 |
Number of channels | 8 | 8 |
Voltage range | [-16 … 16] | [-16 … 16] |
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323