5.3 Configuring the Electrical Models

Circuit Model File Path: <Public Documents>\National Instruments\<NI VeriStand 20XX>\Examples\OPAL-RT\Power Electronics Add-On\6-Phase PMSM Local Control\Circuit Model\PMSM_eHS_UB.mdl

Configuring the 6 Phase PMSM Model

In this example, the PMSM model and associated sensors have been pre-configured. For more information related to machine configuration, please refer to the 6-Phase PMSM BLDC Section. Explore the configuration of the machine by following the steps below.

  • In the Configuration Tree, expand Circuit Model >> Machines and click 6-Ph PMSM BLDC 1 to open the configuration page for the machine.

  • Observe the configured machine parameters. The Input Mapping subsection allows the outputs of the circuit model to be connected to the inputs of the machine.

  • In the Configuration tree, expand 6-Ph PMSM BLDC 1 and click Mechanical Model to view the mechanical model parameters.

  • Confirm that the parameter values match those in the table below.

Machine Configuration

Machine Configuration

Machine Type

PMSM Constant Ld/Lq

Direct Inductance 1 (H)

0.002984

Direct Inductance 2 (H)

0.002984

Quadrature Inductance 1 (H)

0.004576

Quadrature Inductance 2 (H)

0.004576

Permanent Magnetic Flux (Wb)

0.25366

Phase A Resistance (Ohm)

1.2

Phase B Resistance (Ohm)

1.2

Phase C Resistance (Ohm)

1.2

Phase X Resistance (Ohm)

1.2

Phase Y Resistance (Ohm)

1.2

Phase Z Resistance (Ohm)

1.2

Pole Pairs

1

Direct Quadrature Transform Angle Offset

Aligned

Sample Time (s)

1.2E-7

Input Mapping Configuration

Voltage Phase A

Circuit Model 1.Va_inv

Voltage Phase B

Circuit Model 1.Vb_inv

Voltage Phase C

Circuit Model 1.Vc_inv

Voltage Phase X

Circuit Model 1.Vx_inv

Voltage Phase Y

Circuit Model 1.Vy_inv

Voltage Phase Z

Circuit Model 1.Vz_inv

 

 

 

Mechanical Model Configuration

Mechanical Model Configuration

Initial Rotor Angle (Deg)

0

Viscous Damping

0.0019

Static Friction

0.3665

Inertia

0.0167

Mechanical Model Mode (VeriStand Channel)